摘要

In this study, the PMUs are placed to operate in normal and islanded cases taking into account power system observability, reliability, Communication Infrastructure (CI), and latency time associated with this CI. Moreover, the economic study for additional new data transmission paths is considered as well as the preexisting Communication Devices (CDs) and the availability of predefined locations of some PMUs in some buses. The PMUs placement and their communication network topology and link channel capacity are co-optimized simultaneously. Two different approaches are applied to optimize the objective function; the first approach is combined from Binary Teaching Learning Based Optimization Algorithm (BTLBOA) and the Minimum Spanning Tree (MST) algorithm, while the second approach is based on BTLBOA. The proposed approaches are examined using IEEE 118-bus systems.
机译:在本研究中,考虑到电力系统的可观察性,可靠性,通信基础设施(CI)和与此CI相关的等待时间,将PMU放置在正常和孤立的情况下运行。此外,还考虑了对其他新数据传输路径的经济研究,以及先前存在的通信设备(CD)和某些总线中某些PMU的预定位置的可用性。同时共同优化PMU的放置及其通信网络拓扑和链路通道容量。应用了两种不同的方法来优化目标函数。第一种方法是结合基于二进制教学学习的优化算法(BTLBOA)和最小生成树(MST)算法,而第二种方法则是基于BTLBOA。使用IEEE 118总线系统检查了所提出的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号