Validation of the Automated Reading and Incubation System with Sensititre Plates for Antimicrobial Susceptibility Testing

机译:带有敏感性板的自动读数和孵育系统用于抗菌药敏感性测试的验证

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The present study compared the antimicrobial susceptibility testing (AST) results generated by the Automated Incubation and Reading System (ARIS) with custom Sensititre plates (TREK Diagnostic Systems, Cleveland, Ohio) and MicroScan PC10 GP and NUMIC10 GN plates interpreted with the WalkAway-96 system (Dade Behring, West Sacramento, Calif.) for gram-positive (GP) and gram-negative (GN) organisms as part of an in-house validation. A total of 326 isolates (3,689 antimicrobial agent-organism combinations) were evaluated. Sensititre plates were inoculated according to the instructions of the manufacturer with a suspension adjusted to a 0.5 McFarland standard, while the Prompt Inoculation System was used for the MicroScan plates. ARIS and the WalkAway system were used for automated reading of the Sensititre and MicroScan plates, respectively, at 18 to 24 h. The results were analyzed for essential (±1 twofold dilution) and categorical (sensitive, intermediate, or resistant) agreements. Plates that resulted in ARIS interpretations with major (falsely resistant) or very major (falsely susceptible) errors compared to the results obtained with the WalkAway system were read manually to corroborate instrument readings. Isolates for which very major or major errors were obtained and for which the results were not resolved by manual reading were retested in parallel. Isolates for which very major or major errors were obtained and for which the results were not resolved upon repeat testing were tested by the National Committee for Clinical Laboratory Standards M7-A5 frozen reference microdilution method. Essential agreement was 95.8% for 246 GN isolates. The following categorical error rates were obtained for the GN isolates: 1.3% minor errors, 0% major errors, and 0.4% very major errors. For 95 GP isolates, there was 93.5% essential agreement. Categorical error rates for GP isolates were 0.9% minor errors, 0.6% major errors, and 0.4% very major errors. ARIS-Sensititre is a diagnostic system feasible for use for automated AST in a clinical laboratory.
机译:本研究比较了自动孵育和读数系统(ARIS)与定制的Sensititre板(TREK Diagnostic Systems,俄亥俄州克利夫兰)和MicroScan PC10 GP和NUMIC10 GN板(用WalkAway-96解释)生成的抗菌药敏试验(AST)结果。内部验证的一部分,用于革兰氏阳性(GP)和革兰氏阴性(GN)生物的系统(加利福尼亚州西萨克拉曼多的Dade Behring)。总共评估了326种分离物(3,689种抗菌剂-微生物组合)。根据制造商的说明,将敏感板接种至调整为0.5 McFarland标准的悬浮液,而将提示接种系统用于MicroScan板。 ARIS和WalkAway系统分别在18至24 h分别自动读取Sensititre和MicroScan板。对结果进行了必要的(±1两倍稀释度)和明确的(敏感,中间或耐药)协议分析。与WalkAway系统获得的结果相比,手动读取导致ARIS解释有严重错误错误或非常严重错误错误的板,以确认仪器读数。并行重新测试获得非常重大错误的分离物,以及无法通过手动读取解决结果的分离物。由国家临床实验室标准委员会M7-A5冷冻参考微量稀释方法测试了分离出非常重大或重大错误且结果在重复测试后仍未解决的分离株。 246个GN分离株的基本一致性为95.8%。对于GN分离株,获得了以下分类错误率:1.3%的次要错误,0%的主要错误和0.4%的非常重大的错误。对于95个GP分离株,有93.5%的基本一致性。 GP分离株的分类错误率是0.9%的次要错误,0.6%的主要错误和0.4%的非常重大错误。 ARIS-Sensititre是一种诊断系统,可用于临床实验室中的自动AST。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号