首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Improvement of AMPLICOR Human Immunodeficiency Virus Type 1 Viral Load Test (Version 1.5) by Addition of a Coprecipitant during the RNA Isolation Step
【2h】

Improvement of AMPLICOR Human Immunodeficiency Virus Type 1 Viral Load Test (Version 1.5) by Addition of a Coprecipitant during the RNA Isolation Step

机译:通过在RNA分离步骤中添加共沉淀剂来改善AMPLICOR 1型人类免疫缺陷病毒的病毒载量测试(1.5版)

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The effect of the addition of a coprecipitant during the RNA isolation step on the analytical performance of the COBAS AMPLICOR human immunodeficiency virus type 1 (HIV-1) Monitor (version 1.5; Roche) viral load test was tested. Thirty-six specimens including patient samples, positive control samples, and negative control samples were processed in the presence and absence of the Pellet Paint coprecipitant. Specimens processed without the coprecipitant had lower RNA yields, as evidenced by a lower signal for the quantitation standard (QS). In addition, the results for all samples processed with the coprecipitant were acceptable on the basis of the optical density (OD) reading for the QS, whereas the result for one specimen processed without the coprecipitant was unacceptable on the basis of the OD reading for the QS, which required the assay to be repeated. Furthermore, the use of the coprecipitant improved the overall precision of the assay.
机译:测试了在RNA分离步骤中添加共沉淀剂对COBAS AMPLICOR 1型人类免疫缺陷病毒(HIV-1)Monitor(1.5版; Roche)病毒载量测试的分析性能的影响。在有无Pellet Paint共沉淀剂的情况下,对包括患者样品,阳性对照样品和阴性对照样品在内的36个样品进行了处理。没有定量沉淀剂处理的样品RNA产量较低,定量标准品(QS)的信号较低证明了这一点。此外,根据QS的光密度(OD)读数,用共沉淀剂处理的所有样品的结果都是可以接受的,而对于没有共沉淀剂的样品处理的一个样品的结果,根据QS的OD读数是不可接受的。 QS,需要重复测定。此外,共沉淀剂的使用提高了测定的整体精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号