Human immunodeficiency virus type 1 (HIV-1) RNA measurements were evaluated within an externally controlled multilaboratory program. Three external standards (1.5 × 103 to 1.5 × 106 copies/ml) were included in 814 assay runs by four laboratories. Results indicate that HIV-1 RNA levels can be measured with a precision equal to that of the pre-highly active antiretroviral therapy era (standard deviations, ±0.16 to 0.25 log10 units).
机译:在外部控制的多实验室程序中评估了人类1型免疫缺陷病毒(HIV-1)RNA的测量值。四个实验室在814次测定中包括了三种外标(1.5×10 3 至1.5×10 6 拷贝/ ml)。结果表明,HIV-1 RNA的水平可以达到与以前高度活跃的抗逆转录病毒疗法时代相同的精度(标准偏差为±0.16至0.25 log10单位)。