首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Comparison of agar dilution broth microdilution disk diffusion E-test and BACTEC radiometric methods for antimicrobial susceptibility testing of clinical isolates of the Nocardia asteroides complex.
【2h】

Comparison of agar dilution broth microdilution disk diffusion E-test and BACTEC radiometric methods for antimicrobial susceptibility testing of clinical isolates of the Nocardia asteroides complex.

机译:琼脂稀释肉汤微稀释圆盘扩散E检验和BACTEC放射学方法对诺卡氏小行星复合物临床分离株的抗菌药敏测试的比较。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

An evaluation was undertaken to determine the optimal method for the in vitro susceptibility testing of 26 Nocardia asteroides complex isolates to the following antimicrobial agents: amikacin, ampicillin, amoxicillin-clavulanate, ceftriaxone, ciprofloxacin, erythromycin, imipenem, minocycline, and trimethoprim-sulfamethoxazole. Five testing methods were studied including the agar dilution, broth microdilution, and disk diffusion methods, the epsilometer test (E-test), and the BACTEC radiometric method. Results for each antimicrobial agent and each testing method were interpreted as indicating susceptibility, intermediate susceptibility, or resistance according to current guidelines of the National Committee for Clinical Laboratory Standards (NCCLS) for bacteria that grow aerobically and were then compared to a "gold standard" susceptibility test result. The gold standard result for each Nocardia isolate was established by a consensus of the results of the majority of testing methods used in the study. When the results were combined for all antimicrobial agents tested against all Nocardia isolates by all methods, the BACTEC radiometric method produced the highest level of agreement (97.9%) with the consensus results and had the fewest very major (n = 1), major (n = 2), and minor (n = 2) errors. In contrast, the results of the agar dilution method were in least agreement (93.2%) with the consensus results, and this method also produced the most very major (n = 8), major (n = 4), and, along with the disk diffusion method, minor (n = 6) errors. For all test methods, interpretive errors were most frequent when testing ampicillin or amoxicillin-clavulanate. Moreover, for all Nocardia nova isolates tested, ampicillin susceptibility results by any of the testing methods were not in agreement with the results of testing for beta-lactamase by the nitrocefin (Cefinase) disk method. We conclude that among the methods evaluated, the BACTEC radiometric method appeared to be the best for determining the in vitro susceptibilities of members of the N. asteroides complex to a panel of nine antimicrobial agents. However, none of the test methods, including the BACTEC method, accurately predicted the ampicillin resistance of the N. nova isolates tested, all of which produced beta-lactamase. Presuming that this beta-lactamase hydrolyzes ampicillin, this disparity may relate to the NCCLS breakpoints that were used, which may require modification for this antimicrobial agent when tested against N. nova isolates.
机译:进行了评估,以确定26种诺卡氏小行星复合物分离物对以下抗菌剂的体外药敏试验的最佳方法:阿米卡星,氨苄青霉素,阿莫西林-克拉维酸盐,头孢曲松,环丙沙星,红霉素,亚胺培南,米诺环素和甲氧苄氨嘧啶。研究了五种测试方法,包括琼脂稀释法,肉汤微稀释法和圆盘扩散法,epsilometer测试(E-test)和BACTEC辐射法。根据国家临床实验室标准委员会(NCCLS)当前对有氧细菌生长然后再与“黄金标准”进行比较的标准,每种抗微生物剂和每种测试方法的结果均被解释为表示敏感性,中等敏感性或耐药性。药敏试验结果。通过对研究中使用的大多数测试方法的结果达成共识,确定每种诺卡氏菌分离物的金标准结果。当通过所有方法将针对所有诺卡氏菌分离物测试的所有抗微生物剂的结果进行合并时,BACTEC放射法与共识结果的一致性最高(97.9%),并且非常重要(n = 1),主要(n = 1)最少。 n = 2)和次要(n = 2)错误。相比之下,琼脂稀释法的结果与共识结果至少一致(93.2%),并且该方法也产生了非常非常大的结果(n = 8),主要(n = 4),以及磁盘扩散法,较小(n = 6)错误。对于所有测试方法,测试氨苄青霉素或阿莫西林-克拉维酸盐时的解释错误最常见。而且,对于所有测试的诺卡氏菌新星分离物,通过任何一种测试方法测得的氨苄青霉素敏感性结果与通过硝菌素(Cefinase)圆盘法测试β-内酰胺酶的结果均不一致。我们得出的结论是,在所评估的方法中,BACTEC放射法似乎是确定N.asteroids复合体成员对一组9种抗菌剂的体外药敏性的最佳方法。但是,包括BACTEC方法在内的所有测试方法均无法准确预测所测新星猪笼草的氨苄青霉素耐药性,所有这些菌株均产生β-内酰胺酶。假定该β-内酰胺酶水解氨苄西林,则该差异可能与所使用的NCCLS断裂点有关,在针对新星猪笼草分离物进行测试时,可能需要对该抗菌剂进行修饰。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号