首页> 美国卫生研究院文献>other >Reduction of Image Artifacts in Mice by Bladder Flushing with a Novel Double-Lumen Urethral Catheter
【2h】

Reduction of Image Artifacts in Mice by Bladder Flushing with a Novel Double-Lumen Urethral Catheter

机译:新型双腔输尿管膀胱冲洗减少小鼠的图像伪像

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In electron paramagnetic resonance imaging (EPRI), the accumulation of contrast agent in the bladder can create a very large source of signal, often far greater than that of the organ of interest. Mouse model images have become increasingly important in preclinical testing. To minimize bladder accumulation on mouse images, we developed a novel, minimally invasive, MRI/EPRI-friendly procedure for flushing a female mouse bladder. It is also applicable to other imaging techniques, for example, PET, SPECT, etc., where contrast agent accumulation in the bladder is also undesirable. A double-lumen urethral catheter was developed, using a standard IV catheter with a silicone tube extension, having a polyethylene tube threaded into the IV catheter. Flushing of the bladder provides a substantial reduction in artifacts, as shown in images of tumors in mice.
机译:在电子顺磁共振成像(EPRI)中,造影剂在膀胱中的积聚会产生非常大的信号源,通常远大于感兴趣器官的信号源。鼠标模型图像在临床前测试中变得越来越重要。为了最大程度地减少小鼠图像上的膀胱积聚,我们开发了一种新颖的,微创的MRI / EPRI友好程序来冲洗雌性小鼠膀胱。它也适用于其他成像技术,例如PET,SPECT等,其中造影剂在膀胱中的蓄积也是不希望的。开发了一种双腔尿道导管,该导管使用带有硅胶管延伸段的标准IV导管,该聚乙烯导管穿入IV导管中。膀胱潮红可大大减少伪影,如小鼠肿瘤的图像所示。