首页> 美国卫生研究院文献>Journal of Clinical Microbiology >Detection of enterococcal high-level aminoglycoside resistance with MicroScan freeze-dried panels containing newly modified medium and Vitek Gram-Positive Susceptibility cards.
【2h】

Detection of enterococcal high-level aminoglycoside resistance with MicroScan freeze-dried panels containing newly modified medium and Vitek Gram-Positive Susceptibility cards.

机译:使用含有新改良培养基和Vitek革兰氏阳性药敏卡的MicroScan冻干板检测肠球菌高水平氨基糖苷抗性。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Both conventional and modified MicroScan Type 5 panels and Vitek Gram-Positive Susceptibility cards were compared with agar dilution screen plates for their abilities to detect high-level resistance to gentamicin and streptomycin in 235 enterococcal isolates, including 167 Enterococcus faecalis and 63 E. faecium isolates. The modified Type 5 panels contained dextrose-phosphate broth instead of Mueller-Hinton broth in their high-level-resistance screen wells. The sensitivities for detection of gentamicin and streptomycin high-level resistance were 100 and 100% (E. faecalis) and 100 and 94% (E. faecium) for the modified MicroScan panels, 100 and 89% (E. faecalis) and 100 and 98% (E. faecium) for the conventional MicroScan panels, and 81 and 86% (E. faecalis) and 85 and 94% (E. faecium) for the Vitek cards. All specificities were 100% except for the Vitek cards with streptomycin, where it was 96%. Isolates that showed resistance on the streptomycin agar screen plates were rescreened on plates containing 32,000 micrograms/ml to detect ribosomally mediated resistance. For all three systems, every failure to detect streptomycin high-level resistance occurred in isolates with enzymatic, not ribosomal, resistance. The modified MicroScan Type 5 panels are a suitable method for detecting enterococcal high-level resistance to gentamicin and streptomycin. The Vitek cards are too insensitive for this purpose.
机译:将传统和改良的MicroScan 5型面板和Vitek革兰氏阳性药敏卡与琼脂稀释筛板相比,能够检测235种肠球菌分离株(包括167种粪肠球菌和63种粪肠球菌)对庆大霉素和链霉素的高水平抗性。 。改良的5型面板在其高抗性筛选孔中包含葡萄糖磷酸肉汤,而不是Mueller-Hinton肉汤。庆大霉素和链霉素高水平抗药性的检测灵敏度为改良的MicroScan板分别为100和100%(粪肠球菌),100和94%(粪肠球菌),100和89%(粪肠球菌)以及100和100常规MicroScan面板为98%(粪便),Vitek卡为81%和86%(粪便)以及85%和94%(粪便)。除带有链霉素的Vitek卡为96%以外,所有特异性均为100%。在含有32,000微克/毫升的平板上重新筛选在链霉素琼脂筛选平板上显示出抗性的分离株,以检测核糖体介导的抗性。对于所有三个系统,检测到链霉素高水平抗性的每一次失败都发生在具有酶抗性而不是核糖体抗性的分离株中。改良的MicroScan 5型面板是检测肠球菌对庆大霉素和链霉素的高水平耐药性的合适方法。 Vitek卡对于此目的过于敏感。

著录项

相似文献

  • 外文文献
  • 中文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号