A consistent and efficient graphical analysis method to improve the quantification of reversible tracer binding in radioligand receptor dynamic PET studies

机译:一种一致有效的图形分析方法可改善放射性配体受体动态PET研究中可逆示踪剂结合的定量

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The widely used Logan plot in radioligand receptor dynamic PET studies produces marked noise-induced negative biases in the estimates of total distribution volume (DVT) and binding potential (BP). To avoid the inconsistencies in the estimates from the Logan plot, a new graphical analysis method was proposed and characterized in this study. The new plot with plasma input and with reference tissue input was first derived to estimate DVT and BP. A condition was provided to ensure that the estimate from the new plot equals DVT or BP. It was demonstrated theoretically that 1) the statistical expectations of the estimates from the new plot with given input are independent of the noise of the target tissue concentration measured by PET; and 2) the estimates from the time activity curves of regions of interest are identical to those from the parametric images for the new plot. The theoretical results of the new plot were also confirmed by computer simulations and fifty-five human [11C]raclopride dynamic PET studies. By contrast, the marked noise-induced underestimation in the DVT and BP images and noise- induced negative bias in the estimates from the Logan plot were demonstrated by the same data sets used for the new plot. The computational time for generating DVT or BP images in the human studies was reduced by 80% on average by the new plot in contrast to the Logan plot. In conclusion, the new plot is a consistent and computationally efficient graphical analysis method to improve the quantification of reversible tracer binding in radioligand receptor dynamic PET studies.
机译:在放射性配体受体动态PET研究中广泛使用的Logan图在总分布体积(DVT)和结合电位(BP)的估计中产生了明显的噪声诱发的负偏差。为避免Logan图的估计值不一致,本研究提出了一种新的图形分析方法并对其进行了表征。首先推导出具有血浆输入和参考组织输入的新图,以估计DVT和BP。提供了一个条件以确保来自新图的估计等于DVT或BP。从理论上证明了:1)在给定输入的情况下,新图的估计值的统计期望与PET测量的目标组织浓度的噪声无关; 2)感兴趣区域的时间活动曲线的估计与新图的参数图像的估计相同。计算机模拟和55个人[ 11 C]雷氯必利动态PET研究也证实了新图的理论结果。相比之下,Logan图的估计中DVT和BP图像中显着的噪声引起的低估以及噪声引起的负偏差由用于新图的相同数据集证明。与洛根图相比,新图在人类研究中生成DVT或BP图像的计算时间平均减少了80%。总之,新图是一种一致且计算有效的图形分析方法,可改善放射性配体受体动态PET研究中可逆示踪剂结合的定量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号