In 2012, the Reggio Emilia Breast Cancer Screening Program introduced digital mammography in all its facilities at the same time. The aim of this work is to analyze the impact of digital mammography introduction on the recall rate, detection rate, and positive predictive value. The program actively invites women aged 45–74 years. We included women screened in 2011, all of whom underwent film-screen mammography, and all women screened in 2012, all of whom underwent digital mammography. Double reading was used for all mammograms, with arbitration in the event of disagreement. A total of 42,240 women underwent screen-film mammography and 45,196 underwent digital mammography. The recall rate increased from 3.3 to 4.4 % in the first year of digital mammography (relative recall adjusted by age and round 1.46, 95 % CI = 1.37–1.56); the positivity rate for each individual reading, before arbitration, rose from 3 to 5.7 %. The digital mammography recall rate decreased during 2012: after 12 months, it was similar to the recall rate with screen-film mammography. The detection rate was similar: 5.9/1000 and 5.2/1000 with screen-film and digital mammography, respectively (adjusted relative detection rate 0.95, 95 % CI = 0.79–1.13). The relative detection rate for ductal carcinoma in situ remained the same. The introduction of digital mammography to our organized screening program had a negative impact on specificity, thereby increasing the recall rate. The effect was limited to the first 12 months after introduction and was attenuated by the double reading with arbitration. We did not observe any relevant effects on the detection rate.
机译:2012年,雷焦艾米利亚乳腺癌筛查计划同时在其所有设施中引入了数字乳房X线照相术。这项工作的目的是分析数字化乳腺X射线摄影术对查全率,检出率和阳性预测值的影响。该计划积极邀请年龄在45-74岁之间的女性参加。我们纳入了2011年接受过筛查的女性,所有患者均接受了X线钼靶电影摄影,2012年接受了筛查的所有女性,均接受了数字化乳房X线摄影。对所有乳房X光照片均使用了复读,如有分歧,则进行仲裁。共有42,240名妇女接受了银幕乳腺X光摄影,而45,196名接受了数字化乳腺X射线摄影。在数字化乳腺摄影的第一年,召回率从3.3%增加到4.4%(相对召回率根据年龄和1.46轮进行了调整,95%CI = 1.37-1.56);仲裁前,每个阅读的阳性率从3%上升到5.7%。 2012年期间,乳腺X线摄影的召回率有所下降:12个月后,其与胶片X线乳腺摄影的召回率相似。筛查胶片和数字乳腺摄影的检出率相近:分别为5.9 / 1000和5.2 / 1000(调整后的相对检出率0.95,95%CI = 0.79-1.13)。原位导管癌的相对检出率保持不变。将数字化乳腺X线摄影术引入我们有组织的筛查程序对特异性产生负面影响,从而提高了召回率。该影响仅限于引入后的前12个月,并且通过仲裁的双重阅读减弱了。我们没有观察到对检出率的任何相关影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号