The current study presents a quantitative approach towards visually lossless compression ratio (CR) threshold determination of JPEG2000 in digitized mammograms. This is achieved by identifying quantitative image quality metrics that reflect radiologists’ visual perception in distinguishing between original and wavelet-compressed mammographic regions of interest containing microcalcification clusters (MCs) and normal parenchyma, originating from 68 images from the Digital Database for Screening Mammography. Specifically, image quality of wavelet-compressed mammograms (CRs, 10:1, 25:1, 40:1, 70:1, 100:1) is evaluated quantitatively by means of eight image quality metrics of different computational principles and qualitatively by three radiologists employing a five-point rating scale. The accuracy of the objective metrics is investigated in terms of (1) their correlation (r) with qualitative assessment and (2) ROC analysis (Az index), employing pooled radiologists’ rating scores as ground truth. The quantitative metrics mean square error, mean absolute error, peak signal-to-noise ratio, and structural similarity demonstrated strong correlation with pooled radiologists’ ratings (r, 0.825, 0.823, −0.825, and −0.826, respectively) and the highest area under ROC curve (Az, 0.922, 0.920, 0.922, and 0.922, respectively). For each quantitative metric, the highest accuracy values of corresponding ROC curves were used to define metric cut-off values. The metrics cut-off values were subsequently used to suggest a visually lossless CR threshold, estimated to be between 25:1 and 40:1 for the dataset analyzed. Results indicate the potential of the quantitative metrics approach in predicting visually lossless CRs in case of MCs in mammography.
机译:当前的研究提出了一种量化方法,用于确定数字化乳房X光照片中JPEG2000的视觉无损压缩比(CR)阈值。这是通过确定定量图像质量指标来实现的,这些指标反映了放射科医生在区分包含微钙化簇(MC)和正常薄壁组织的原始和小波压缩的乳房X线摄影感兴趣区域时所产生的视觉感知,这些图像来自于用于筛查X线摄影的数字数据库中的68张图像。具体而言,通过八个不同计算原理的图像质量指标对小波压缩的乳房X光照片(CRs,10:1、25:1、40:1、70:1、100:1)的图像质量进行定量评估,并通过三个定性定性放射科医生采用五点等级量表。客观指标的准确性是根据(1)它们的相关性(r)进行定性评估和(2)ROC分析(Az指数)进行的,这些方法采用了放射线医师的综合评分作为地面真实性。定量指标的均方误差,平均绝对误差,峰信噪比和结构相似性表明与放射线专家的评分(分别为r,0.825、0.823,-0.825和-0.826)和最高区域高度相关在ROC曲线下(分别为Az,0.922、0.920、0.922和0.922)。对于每个定量指标,使用相应ROC曲线的最高准确性值来定义指标截止值。随后使用度量标准截断值来建议视觉无损CR阈值,对于分析的数据集,CR阈值估计在25:1到40:1之间。结果表明,定量指标方法在乳腺X线摄影术中预测视觉无损CR的潜力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号