首页> 美国卫生研究院文献>Journal of Digital Imaging >Evaluation of the Image Quality of Temporal Subtraction Images Produced Automatically in a PACS Environment
【2h】

Evaluation of the Image Quality of Temporal Subtraction Images Produced Automatically in a PACS Environment

机译:在PACS环境中自动生成的时间相减图像的图像质量评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of the study is to evaluate the reliable production of temporal subtraction images in a picture archiving and communication system environment and to establish objective criteria for the evaluation of image quality. A total of 117 temporal subtraction chest images (55 in the upright position, 62 in the supine position) were obtained in five consecutive days. In all of these, we confirmed that there were no interval changes on the original images, and cases with diffuse lung disease were excluded. The temporal subtraction images were classified by three chest radiologists into five levels: 5, excellent; 4, good; 3, acceptable; 2, poor; and 1, very poor. The following were examined: (1) the yield of adequate quality of the temporal subtraction images; (2) whether the temporal subtraction images were obtained in the warping or nonwarping mode; and (3) the correlation of the overall subjective image quality with the relative shift angles, relative shift distances, and the standard deviation of gray levels in the temporal subtraction images. The percentages of acceptable temporal subtraction images were 100% and 66% in the upright and supine positions, respectively. Sixteen (26%) of the 62 supine-position images were made in nonwarping mode, whereas all upright images were made in warping mode. Significant correlations were obtained in the relative shift angle (P < 0.05), relative horizontal shift distance (P < 0.05), and standard deviation of gray levels (P < 0.0001). Temporal subtraction images with acceptable image quality were obtained in the upright position. The objective criteria may be useful for the evaluation of image quality.
机译:该研究的目的是评估在图像存档和通信系统环境中时间减法图像的可靠产生,并建立评估图像质量的客观标准。在连续五天内共获得117个颞部减影胸部图像(垂直位置55幅,仰卧位置62幅)。在所有这些中,我们确认原始图像没有间隔变化,并且排除了弥漫性肺部疾病的病例。三位胸部放射医师将颞下颌图像分为五个级别:5,极佳; 4,好; 3,可接受; 2,差; 1,非常差。检查了以下内容:(1)适当质量的时间相减图像的产量; (2)时间减法图像是在弯曲还是非弯曲模式下获得的; (3)总体主观图像质量与时间相减图像中的相对偏移角,相对偏移距离和灰度标准偏差的相关性。在直立和仰卧位置可接受的时间减影图像的百分比分别为100%和66%。 62个仰卧位图像中有16个(占26%)是在非翘曲模式下制作的,而所有直立图像都是在翘曲模式下制作的。在相对位移角(P <0.05),相对水平位移距离(P <0.05)和灰度标准偏差(P <0.0001)上获得了显着的相关性。在直立位置获得了具有可接受图像质量的时间减影图像。客观标准对于评估图像质量可能有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号