The purpose of this project was to determine whether Contrast Limited Adaptive Histogram Equalization (CLAHE) improves detection of simulated spiculations in dense mammograms. Lines simulating the appearance of spiculations, a common marker of malignancy when visualized with masses, were embedded in dense mammograms digitized at 50 micron pixels, 12 bits deep. Film images with no CLAHE applied were compared to film images with nine different combinations of clip levels and region sizes applied. A simulated spiculation was embedded in a background of dense breast tissue, with the orientation of the spiculation varied. The key variables involved in each trial included the orientation of the spiculation, contrast level of the spiculation and the CLAHE settings applied to the image. Combining the 10 CLAHE conditions, 4 contrast levels and 4 orientations gave 160 combinations. The trials were constructed by pairing 160 combinations of key variables with 40 backgrounds. Twenty student observers were asked to detect the orientation of the spiculation in the image. There was a statistically significant improvement in detection performance for spiculations with CLAHE over unenhanced images when the region size was set at 32 with a clip level of 2, and when the region size was set at 32 with a clip level of 4. The selected CLAHE settings should be tested in the clinic with digital mammograms to determine whether detection of spiculations associated with masses detected at mammography can be improved.
机译:该项目的目的是确定对比度受限的自适应直方图均衡化(CLAHE)是否能改善对密集乳腺X线图中模拟细针的检测。模拟细刺的出现的线(当用肿块可视化时是恶性的常见标志)被嵌入密集的乳房X线照片中,以50微米像素(12位深)数字化。将未应用CLAHE的胶片图像与应用了九种不同剪辑级别和区域大小组合的胶片图像进行了比较。模拟的针刺被嵌入到致密的乳房组织的背景中,针刺的方向各不相同。每个试验中涉及的关键变量包括针刺的方向,针刺的对比度水平以及应用于图像的CLAHE设置。结合10种CLAHE条件,4种对比度水平和4种方向,可以得到160种组合。通过将160个关键变量组合与40个背景配对来构建试验。要求二十名学生观察者检测图像中针刺的方向。当将区域大小设置为32的剪辑级别为2时,以及将区域大小设置为32的剪辑级别为4时,与未增强的图像相比,使用CLAHE进行的针刺的检测性能在统计上有显着改善。应在临床中使用数字X线摄片检查测试这些设置,以确定是否可以改善与在X线摄片机上检测到的肿块相关的针刺的检测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号