2-D transrectal ultrasound (TRUS) is being used in guiding prostate biopsies and treatments. In many cases, the TRUS probes are moved manually or mechanically to acquire volumetric information, making the imaging slow, user-dependent and unreliable. A real-time 3-D TRUS system could improve reliability and volume rates of imaging during these procedures. In this paper, we present a 5 MHz cylindrical dual-layer transducer array capable of real-time 3-D transrectal ultrasound without any mechanically moving parts. Compared to fully-sampled 2-D arrays, this design substantially reduces the channel count and fabrication complexity. This dual-layer transducer uses PZT elements for transmit and P[VDF-TrFE] copolymer elements for receive, respectively. The mechanical flexibility of both diced PZT and copolymer makes it practical for transrectal applications. Full synthetic aperture 3-D data sets were acquired by interfacing the transducer with a Verasonics Data Acquisition System (VDAS). Offline 3-D beamforming was then performed to obtain volumes of two wire phantoms and a cyst phantom. Generalized coherence factor (GCF) was applied to improve the contrast of images. The measured −6 dB fractional bandwidth of the transducer was 62% with a center frequency of 5.66 MHz. The measured lateral beamwidths were 1.28 mm and 0.91 mm in transverse and longitudinal directions respectively, compared with a simulated beamwidth of 0.92 mm and 0.74 mm.
机译:2-D经癌超声(TRU)用于引导前列腺活组织检查和治疗。在许多情况下,TRUS探针手动或机械地移动以获取体积信息,使成像缓慢,用户依赖性和不可靠。实时3-D TRUS系统可以提高这些程序期间成像的可靠性和体积率。在本文中,我们介绍了一个5 MHz圆柱双层换能器阵列,其能够实时3-D经频超声波,而没有任何机械移动部件。与完全采样的2-D阵列相比,该设计基本上降低了通道计数和制造复杂性。该双层换能器分别使用用于接收的发射和P [VDF-TRFE]共聚物元素的PZT元素。 Diced PZT和共聚物的机械柔韧性使其成为逾越应用的实用性。通过将换能器与Verasonics数据采集系统(VDA)连接来获取完整的合成孔径3-D数据集。然后执行离线3-D波束形成以获得两种线模和囊体的体积。应用广泛的相干因子(GCF)来改善图像的对比度。换能器的测量-6 dB分数带宽为62%,中心频率为5.66MHz。分别测量的横向波束宽度分别为横向和纵向方向为1.28mm和0.91mm,与0.92mm和0.74mm的模拟波束宽度相比。

著录项

  • 期刊名称 other
  • 作者单位
  • 年(卷),期 -1(34),3
  • 年度 -1
  • 页码 181–195
  • 总页数 23
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号