首页> 美国卫生研究院文献>other >Experimental demonstration of benchtop x-ray fluorescence computed tomography (XFCT) of gold nanoparticle-loaded objects using lead- and tin-filtered polychromatic cone-beams
【2h】

Experimental demonstration of benchtop x-ray fluorescence computed tomography (XFCT) of gold nanoparticle-loaded objects using lead- and tin-filtered polychromatic cone-beams

机译:使用铅和锡过滤多色锥束金纳米颗粒加载的对象的台式X射线荧光计算机断层摄影(XFCT)的实验演示

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This report presents the first experimental demonstration, to our knowledge, of benchtop polychromatic cone-beam x-ray fluorescence computed tomography (XFCT) for a simultaneous determination of the spatial distribution and amount of gold nanoparticles (GNPs) within small-animal-sized objects. The current benchtop experimental setup successfully produced XFCT images accurately showing the regions containing small amount of GNPs (on the order of 0.1 mg) within a 3-cm diameter plastic phantom. In particular, the performance of the current XFCT setup was improved remarkably (e.g., at least a factor of 3 reduction in XFCT scan time) using a tin-filtered polychromatic beam in comparison with a lead-filtered beam. The results of this study strongly suggest the current benchtop XFCT configuration can be made practical with a few modifications such as the deployment of array detectors, while meeting realistic constraints on x-ray dose, scan time, and image resolution for routine pre-clinical in-vivo imaging with GNPs.
机译:据我们所知,本报告提供了台式多色锥束X射线荧光计算机断层扫描(XFCT)的第一个实验演示,用于同时测定小动物物体中金纳米颗粒(GNP)的空间分布和数量。当前的台式实验装置成功产生了XFCT图像,准确地显示了直径为3厘米的塑料幻影中包含少量GNP(约0.1 mg)的区域。特别地,与铅过滤光束相比,使用锡过滤的多色光束显着改善了当前XFCT设置的性能(例如,XFCT扫描时间至少减少了3倍)。这项研究的结果有力地表明,当前的台式XFCT配置可以进行一些修改,例如部署阵列检测器,同时满足X射线剂量,扫描时间和常规临床前成像分辨率的实际限制,从而可以实现实际应用。 GNP进行活体成像。

著录项