BackgroundA recent out-of-hospital cardiac arrest (OHCA) clinical trial showed improved survival to hospital discharge (HD) with favorable neurologic function for patients with cardiac arrest of cardiac origin treated with active compression decompression cardiopulmonary resuscitation (CPR) plus an impedance threshold device (ACD+ICD) versus standard (S) CPR. The current analysis examined whether treatment with ACD+ITD is more effective than standard (S-CPR) for all cardiac arrests of non-traumatic origin, regardless of the aetiology.
机译:背景一项最近的院外心脏骤停(OHCA)临床试验显示,通过主动加压减压心肺复苏(CPR)和阻抗阈值设备治疗的心源性心脏骤停患者可以改善出院生存率(HD),并具有良好的神经功能(ACD + ICD)与标准(S)CPR。当前的分析检查了对于所有非创伤性心脏骤停,无论病因如何,ACD + ITD治疗是否比标准治疗(S-CPR)更有效。