Ultrasonic Incisions Produce Less Inflammatory Mediator Response during Early Healing than Electrosurgical Incisions

机译:与电外科切口相比超声切口在早期愈合过程中产生的炎症介质反应更少

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

As the use of laparoscopic surgery has become more widespread in recent years, the need has increased for minimally-invasive surgical devices that effectively cut and coagulate tissue with reduced tissue trauma. Although electrosurgery (ES) has been used for many generations, newly-developed ultrasonic devices (HARMONIC® Blade, HB) have been shown at a macroscopic level to offer better coagulation with less thermally-induced tissue damage. We sought to understand the differences between ES and HB at a microscopic level by comparing mRNA transcript and protein responses at the 3-day timepoint to incisions made by the devices in subcutaneous fat tissue in a porcine model. Samples were also assessed via histological examination. ES-incised tissue had more than twice as many differentially-expressed genes as HB (2,548 vs 1,264 respectively), and more differentially-expressed proteins (508 vs 432) compared to control (untreated) tissue. Evaluation of molecular functions using Gene Ontology showed that gene expression changes for the energized devices reflected the start of wound healing, including immune response and inflammation, while protein expression showed a slightly earlier stage, with some remnants of hemostasis. For both transcripts and proteins, ES exhibited a greater response than HB, especially in inflammatory mediators. These findings were in qualitative agreement with histological results. This study has shown that transcriptomics and proteomics can monitor the wound healing response following surgery and can differentiate between surgical devices. In agreement with clinical observations, electrosurgery was shown to incur a greater inflammatory immune response than an ultrasonic device during initial iatrogenic wound healing.
机译:近年来,随着腹腔镜手术的使用变得越来越广泛,对有效减少组织创伤并能有效切开和凝结组织的微创手术设备的需求不断增加。尽管电外科手术(ES)已经使用了许多代,但从宏观角度显示了新开发的超声波设备(HARMONIC®Blade,HB),可以提供更好的凝结效果,并减少热引起的组织损伤。我们试图通过比较3天时间点在猪模型中皮下脂肪组织中器械产生的切口的mRNA转录和蛋白质反应,从微观水平了解ES和HB之间的差异。还通过组织学检查评估样品。与对照(未经处理)的组织相比,ES切除的组织的差异表达基因的数量是HB的两倍多(分别为2548和1,264),差异表达的蛋白质(508和432)更多。使用基因本体论对分子功能进行的评估表明,通电设备的基因表达变化反映了伤口愈合的开始,包括免疫反应和炎症,而蛋白质表达则处于稍早的阶段,并有一定的止血作用。对于转录物和蛋白质,ES表现出比HB更大的反应,尤其是在炎症介质中。这些发现与组织学结果在质量上是一致的。这项研究表明,转录组学和蛋白质组学可以监测手术后的伤口愈合反应,并可以区分手术器械。与临床观察结果一致,在最初的医源性伤口愈合过程中,电外科手术比超声器械具有更大的炎症免疫反应。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号