首页> 美国卫生研究院文献>other >Test-Retest Reliability of Innovated Strength Tests for Hip Muscles
【2h】

Test-Retest Reliability of Innovated Strength Tests for Hip Muscles

机译:创新的臀部肌肉力量测试的重测可靠性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The burden of hip muscles weakness and its relation to other impairments has been well documented. It is therefore a pre-requisite to have a reliable method for clinical assessment of hip muscles function allowing the design and implementation of a proper strengthening program. Motor-driven dynamometry has been widely accepted as the gold-standard for lower limb muscle strength assessment but is mainly related to the knee joint. Studies focusing on the hip joint are less exhaustive and somewhat discrepant with regard to optimal participants position, consequently influencing outcome measures. Thus, we aimed to develop a standardized test setup for the assessment of hip muscles strength, i.e. flexors/extensors and abductors/adductors, with improved participant stability and to define its psychometric characteristics. Eighteen participants performed unilateral isokinetic and isometric contractions of the hip muscles in the sagittal and coronal plane at two separate occasions. Peak torque and normalized peak torque were measured for each contraction. Relative and absolute measures of reliability were calculated using the intraclass correlation coefficient and standard error of measurement, respectively. Results from this study revealed higher levels of between-day reliability of isokinetic/isometric hip abduction/flexion peak torque compared to existing literature. The least reliable measures were found for hip extension and adduction, which could be explained by a less efficient stabilization technique. Our study additionally provided a first set of reference normalized data which can be used in future research.
机译:臀部肌肉无力的负担及其与其他障碍的关系已得到充分证明。因此,必须有一种可靠的方法来进行髋部肌肉功能的临床评估,从而能够设计和实施适当的强化程序。电机测功已被广泛接受为下肢肌肉力量评估的金标准,但主要与膝关节有关。侧重于髋关节的研究较不详尽,并且在最佳参与者位置方面有些差异,因此影响结果指标。因此,我们旨在开发一种标准化的测试装置,用于评估髋部肌肉的力量,即屈肌/伸肌和外展肌/内收肌,并改善参与者的稳定性并定义其心理测量特征。 18名参与者在两个不同的情况下分别在矢状和冠状面进行了髋部肌肉的单侧等速和等距收缩。测量每个收缩的峰值扭矩和归一化峰值扭矩。分别使用类内相关系数和测量的标准误差来计算可靠性的相对和绝对度量。这项研究的结果表明,与现有文献相比,等速/等距髋关节外展/屈曲峰值扭矩的日间可靠性更高。发现髋关节伸展和内收的最不可靠的措施,可以用效率较低的稳定技术来解释。我们的研究还提供了第一套参考归一化数据,可以在将来的研究中使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号