Effect of injection technique on temporal parametric imaging derived fromdigital subtraction angiography in patient specific phantoms

机译:注入技术对时间参数成像的影响患者体模中的数字减影血管造影

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Parametric imaging maps (PIM’s) derived from digital subtraction angiography (DSA) for the cerebral arterial flow assessment in clinical settings have been proposed, but experiments have yet to determine the reliability of such studies. For this study, we have observed the effects of different injection techniques on PIM’s. A flow circuit set to physiologic conditions was created using an internal carotid artery phantom. PIM’s were derived for two catheter positions, two different contrast bolus injection volumes (5ml and 10 ml), and four injection rates (5, 10, 15 and 20 ml/s). Using a gamma variate fitting approach, we derived PIM’s for mean-transit-time (MTT), time-to-peak (TTP) and bolus-arrivaltime (BAT). For the same injection rates, a larger bolus resulted in an increased MTT and TTP, while a faster injection rate resulted in a shorter MTT, TTP, and BAT. In addition, the position of the catheter tip within the vasculature directly affected the PIM. The experiment showed that the PIM is strongly correlated with the injection conditions, and, therefore, they have to be interpreted with caution. PIM images must be taken from the same patient to be able to be meaningfully compared. These comparisons can include pre- and post-treatment images taken immediately before and after an interventional procedure or simultaneous arterial flow comparisons through the left and right cerebral hemispheres. Due to the strong correlation between PIMand injection conditions, this study indicates that this assessment method should be usedonly to compare flow changes before and after treatment within the same patient using thesame injection conditions.
机译:已经提出了从数字减影血管造影(DSA)得出的用于临床环境中脑动脉血流评估的参数化成像图(PIM),但尚未通过实验确定这种研究的可靠性。在这项研究中,我们观察到了不同注射技术对PIM的影响。使用颈内动脉体模创建了设置为生理条件的流动回路。 PIM是针对两个导管位置,两个不同的造影剂推注体积(5 ml和10 ml)以及四个注射速率(5、10、15和20 ml / s)得出的。使用伽玛变量拟合方法,我们得出了平均通过时间(MTT),到达峰值时间(TTP)和快速到达时间(BAT)的PIM。对于相同的注射速率,大剂量推注会导致MTT和TTP增加,而更快的注射速率会导致较短的MTT,TTP和BAT。另外,导管尖端在脉管系统内的位置直接影响PIM。实验表明,PIM与注入条件密切相关,因此,必须谨慎解释它们。 PIM图像必须来自同一位患者,以便能够进行有意义的比较。这些比较可以包括在介入手术之前和之后立即拍摄的治疗前和治疗后图像,或者通过左和右脑半球同时进行的动脉血流比较。由于PIM之间的相关性很强和注射条件,这项研究表明应使用这种评估方法仅用于比较同一患者在治疗前后的流量变化相同的注射条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号