Effects of Dextrose and Lipopolysaccharide on the Corrosion Behavior of a Ti-6Al-4V Alloy with a Smooth Surface or Treated with Double-Acid-Etching

机译:葡萄糖和脂多糖对表面光滑或双酸蚀处理的Ti-6Al-4V合金腐蚀行为的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Diabetes and infections are associated with a high risk of implant failure. However, the effects of such conditions on the electrochemical stability of titanium materials remain unclear. This study evaluated the corrosion behavior of a Ti-6Al-4V alloy, with a smooth surface or conditioned by double-acid-etching, in simulated body fluid with different concentrations of dextrose and lipopolysaccharide. For the electrochemical assay, the open-circuit-potential, electrochemical impedance spectroscopy, and potentiodynamic test were used. The disc surfaces were characterized by scanning electron microscopy and atomic force microscopy. Their surface roughness and Vickers microhardness were also tested. The quantitative data were analyzed by Pearson's correlation and independent t-tests (α = 0.05). In the corrosion parameters, there was a strong lipopolysaccharide correlation with the Ipass (passivation current density), Cdl (double-layer capacitance), and Rp (polarization resistance) values (p<0.05) for the Ti-6Al-4V alloy with surface treatment by double-acid-etching. The combination of dextrose and lipopolysaccharide was correlated with the Icorr (corrosion current density) and Ipass (p<0.05). The acid-treated groups showed a significant increase in Cdl values and reduced Rp values (p<0.05, t-test). According to the topography, there was an increase in surface roughness (R2 = 0.726, p<0.0001 for the smooth surface; R2 = 0.405, p = 0.036 for the double-acid-etching-treated surface). The microhardness of the smooth Ti-6Al-4V alloy decreased (p<0.05) and that of the treated Ti-6Al-4V alloy increased (p<0.0001). Atomic force microscopy showed changes in the microstructure of the Ti-6Al-4V alloy by increasing the surface thickness mainly in the group associated with dextrose and lipopolysaccharide. The combination of dextrose and lipopolysaccharide affected the corrosion behavior of the Ti-6Al-4V alloy surface treated with double-acid-etching. However, no dose-response corrosion behavior could be observed. These results suggest a greater susceptibility to corrosion of titanium implants in diabetic patients with associated infections.
机译:糖尿病和感染与植入失败的高风险有关。然而,这种条件对钛材料的电化学稳定性的影响仍然不清楚。这项研究评估了具有光滑表面或通过双酸腐蚀处理的Ti-6Al-4V合金在具有不同浓度葡萄糖和脂多糖的模拟体液中的腐蚀行为。对于电化学测定,使用开路电势,电化学阻抗谱和电位动力学测试。盘表面通过扫描电子显微镜和原子力显微镜表征。还测试了它们的表面粗糙度和维氏显微硬度。定量数据通过皮尔森相关性和独立t检验进行分析(α= 0.05)。在腐蚀参数中,带有表面的Ti-6Al-4V合金的脂多糖与Ipass(钝化电流密度),Cdl(双层电容)和Rp(极化电阻)值(p <0.05)具有很强的相关性。通过双酸蚀刻处理。葡萄糖和脂多糖的组合与Icorr(腐蚀电流密度)和Ipass相关(p <0.05)。酸处理组显示Cdl值显着增加,Rp值降低(p <0.05,t检验)。根据形貌,表面粗糙度有所增加(R 2 = 0.726,p <0.0001为光滑表面; R 2 = 0.405,p = 0.036)。双重酸蚀处理过的表面)。光滑的Ti-6Al-4V合金的显微硬度降低(p <0.05),而经过处理的Ti-6Al-4V合金的显微硬度提高(p <0.0001)。原子力显微镜显示,主要是在与葡萄糖和脂多糖有关的组中,通过增加表面厚度,Ti-6Al-4V合金的微观结构发生了变化。葡萄糖和脂多糖的组合影响了用双酸腐蚀处理的Ti-6Al-4V合金表面的腐蚀行为。但是,没有观察到剂量反应腐蚀行为。这些结果表明,在具有相关感染的糖尿病患者中,钛植入物的腐蚀敏感性更高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号