The effect of acquisition geometry in digital breast tomosynthesis (DBT) was evaluated with studies of contrast-to-noise ratios (CNRs) and observer preference. Contrast-detail (CD) test objects in 5 cm thick phantoms with breast-like backgrounds were imaged. Twelve different angular acquisitions (average glandular dose for each ~1.1 mGy) were performed ranging from narrow angle 16° with 17 projection views (16d17p) to wide angle 64d17p. Focal slices of SART-reconstructed images of the CD arrays were selected for CNR computations and the reader preference study. For the latter, pairs of images obtained with different acquisition geometries were randomized and scored by 7 trained readers. The total scores for all images and readings for each acquisition geometry were compared as were the CNRs. In general, readers preferred images acquired with wide angle as opposed to narrow angle geometries. The mean percent preferred was highly correlated with tomosynthesis angle (R=0.91). The highest scoring geometries were 60d21p (95%), 64d17p (80%), and 48d17p (72%); the lowest scoring were 16d17p (4%), 24d9p (17%) and 24d13p (33%). The measured CNRs for the various acquisitions showed much overlap but were overall highest for wide-angle acquisitions. Finally, the mean reader scores were well correlated with the mean CNRs (R=0.83).
机译:通过研究对比噪声比(CNR)和观察者偏好,评估了采集几何形状在数字化乳房断层合成(DBT)中的作用。对具有胸部样背景的5厘米厚幻影中的对比度细节(CD)测试对象成像。进行了十二个不同的角度采集(每个〜1.1 mGy的平均腺体剂量),范围从具有17个投影视图的窄角16°(16d17p)到广角64d17p。选择CD阵列的SART重建图像的焦点切片进行CNR计算和读者偏好研究。对于后者,将对具有不同采集几何形状的图像对进行随机分配,并由7位训练有素的读者进行评分。比较所有图像的总分和每种采集几何结构的读数,以及CNR。通常,与偏角几何形状相比,读者更喜欢使用广角图像。优选的平均百分比与断层合成角高度相关(R = 0.91)。得分最高的几何是60d21p(95%),64d17p(80%)和48d17p(72%);得分最低的是16d17p(4%),24d9p(17%)和24d13p(33%)。各种采集的CNR值显示出很多重叠,但广角采集总体上最高。最后,平均读者得分与平均CNR密切相关(R = 0.83)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号