Heat Sink Effect on Tumor Ablation Characteristics as Observed in Monopolar Radiofrequency Bipolar Radiofrequency and Microwave Using Ex Vivo Calf Liver Model

机译:使用体外小牛肝模型在单极射频双极射频和微波中观察到散热片对肿瘤消融特性的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Thermal ablation of liver tumors near large blood vessels is affected by the cooling effect of blood flow, leading to incomplete ablation. Hence, we conducted a comparative investigation of heat sink effect in monopolar (MP) and bipolar (BP) radiofrequency ablation (RFA), and microwave (MW) ablation devices.With a perfused calf liver, the ablative performances (volume, mass, density, dimensions), with and without heat sink, were measured. Heat sink was present when the ablative tip of the probes were 8.0 mm close to a major hepatic vein and absent when >30 mm away. Temperatures (T1 and T2) on either side of the hepatic vein near the tip of the probes, heating probe temperature (T3), outlet perfusate temperature (T4), and ablation time were monitored.With or without heat sink, BP radiofrequency ablated a larger volume and mass, compared with MP RFA or MW ablation, with latter device producing the highest density of tissue ablated. MW ablation produced an ellipsoidal shape while radiofrequency devices produced spheres.Percentage heat sink effect in Bipolar radiofrequency : Mono-polar radiofrequency : Microwave was (Volume) 33:41:22; (mass) 23:56:34; (density) 9.0:26:18; and (relative elipscity) 5.8:12.9:1.3, indicating that BP and MW devices were less affected.Percentage heat sink effect on time (minutes) to reach maximum temperature (W) = 13.28:9.2:29.8; time at maximum temperature (X) is 87:66:16.66; temperature difference (Y) between the thermal probes (T3) and the temperature (T1 + T2)/2 on either side of the hepatic vessel was 100:87:20; and temperature difference between the (T1 + T2)/2 and temperature of outlet circulating solution (T4), Z was 20.33:30.23:37.5.MW and BP radiofrequencies were less affected by heat sink while MP RFA was the most affected. With a single ablation, BP radiofrequency ablated a larger volume and mass regardless of heat sink.
机译:大血管附近肝肿瘤的热消融受血流冷却作用的影响,导致不完全消融。因此,我们对单极(MP)和双极(BP)射频消融(RFA)和微波(MW)消融装置中的散热效果进行了比较研究。对于小牛灌注肝,其消融性能(体积,质量,密度) (尺寸),有无散热器。当探头的消融尖端靠近肝大静脉时为8.0毫米,则存在散热片;而当距离大于30毫米时,则不存在散热器。监测探头尖端附近肝静脉两侧的温度(T1和T2),加热探头温度(T3),出口灌注液温度(T4)和消融时间。在有或没有散热器的情况下,BP射频消融与MP RFA或MW消融相比,体积和质量更大,后者的设备产生的组织消融密度最高。微波消融产生椭圆形,而射频装置产生球体。双极射频的散热率百分比:单极射频:微波(体积)33:41:22; (质量)23:56:34; (密度)9.0:26:18; 5.8:12.9:1.3,表明BP和MW设备受到的影响较小。散热片对达到最高温度的时间(分钟)的影响百分比(W)= 13.28:9.2:29.8;最高温度(X)的时间为87:66:16.66;热探针(T3)与肝容器任一侧的温度(T1 ++ T2)/ 2之间的温差(Y)为100:87:20。 (T1 + T2)/ 2与出口循环液温度(T4)之间的温差,Z为20.33:30.23:37.5。MW和BP射频受散热器的影响较小,而MP RFA影响最大。一次消融,BP射频消融了更大的体积和质量,与散热片无关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号