In this work, we present a computationally efficient image-derived volume mesh generation approach for vasculatures that implements spatially varying patient-specific wall thickness with a novel inward extrusion of the wall surface mesh. Multi-domain vascular meshes with arbitrary numbers, locations, and patterns of both iliac bifurcations and thrombi can be obtained without the need to specify features or landmark points as input. In addition, the mesh output is coordinate-frame independent and independent of the image grid resolution with high dimensional accuracy and mesh quality, devoid of errors typically found in off-the-shelf image-based model generation workflows. The absence of deformable template models or Cartesian grid-based methods enables the present approach to be robust by handling aneurysmatic geometries with highly irregular shapes, arterial branches nearly parallel to the image plane, and variable wall thickness. The assessment of the methodology was based on i) estimation of the surface reconstruction accuracy, ii) validation of the output mesh using an aneurysm phantom, and iii) benchmarking the volume mesh quality against other frameworks. For the phantom image dataset (pixel size 0.105 mm; slice spacing 0.7 mm; mean wall thickness 1.401 ± 0.120 mm), the average wall thickness in the mesh was 1.459 ± 0.123 mm. The absolute error in average wall thickness was 0.060 ± 0.036 mm, or about 8.6% of the largest image grid spacing (0.7 mm) and 4.36% of the actual mean wall thickness. Mesh quality metrics and the ability to reproduce regional variations of wall thickness were found superior to similar alternative frameworks.
机译:在这项工作中,我们为脉管系统提出了一种计算有效的图像衍生体积网格生成方法,该方法通过壁面网格的新型向内挤压实现空间变化的患者特定壁厚。无需指定特征或界标点作为输入,即可获得具有任意数量,位置和c分支和血栓图案的多域血管网。此外,网格输出是独立于坐标系的,并且独立于图像网格的分辨率,具有较高的尺寸精度和网格质量,而不会出现通常在基于图像的现有模型生成工作流程中发现的错误。缺少可变形模板模型或基于笛卡尔网格的方法,可以通过处理高度不规则形状,几乎平行于图像平面的动脉分支以及可变壁厚的动脉瘤几何来使本方法变得可靠。方法学的评估基于:i)估计表面重建的准确性; ii)使用动脉瘤模型对输出网格进行验证,以及iii)对照其他框架对体积网格质量进行基准测试。对于幻像图像数据集(像素大小0.105毫米;切片间距0.7毫米;平均壁厚1.401±0.120毫米),网格中的平均壁厚为1.459±0.123毫米。平均壁厚的绝对误差为0.060±0.036 mm,约占最大图像栅格间距(0.7 mm)的8.6%和实际平均壁厚的4.36%。发现网格质量指标和再现壁厚区域差异的能力优于类似的替代框架。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号