首页> 美国卫生研究院文献>other >MEG and EEG demonstrate similar test-retest reliability of the 40 Hz auditory steady-state response
【2h】

MEG and EEG demonstrate similar test-retest reliability of the 40 Hz auditory steady-state response

机译:MEG和EEG证明了40 Hz听觉稳态响应的类似重测可靠性

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The auditory steady-state response (ASSR) is increasingly being used as a biomarker in neuropsychiatric disorders, but research investigating the test-retest reliability of this measure is needed. We previously reported ASSR reliability, measured by electroencephalography (EEG), to 40 Hz amplitude-modulated white noise and click train stimuli. The purpose of the current study was to (a) assess the reliability of the MEG-measured ASSR to 40 Hz amplitude-modulated white noise and click train stimuli, and (b) compare test-retest reliability between MEG and EEG measures of ASSR, which has not previously been investigated. Additionally, impact of stimulus parameter choice on reliability was assessed, by comparing responses to white noise and click train stimuli. Test-retest reliability, across sessions approximately one week apart, was assessed in 17 healthy adults. On each study day, participants completed two passive listening tasks (white noise and click train stimuli) during separate MEG and EEG recordings. Between-session correlations for evoked power and inter-trial phase coherence (ITPC) were assessed following source-space projection. Overall, the MEG-measured ASSR was significantly correlated between sessions (p < 0.05, FDR corrected), suggesting acceptable test-retest reliability. Results suggest greater response reproducibility for ITPC compared to evoked responses and for click train compared to white noise stimuli, although further study is warranted. No significant differences in reliability were observed between MEG and EEG measures, suggesting they are similarly reliable. This work supports use of the ASSR as a biomarker in clinical interventions with repeated measures.
机译:听觉稳态反应(ASSR)越来越多地被用作神经精神疾病的生物标志物,但是需要研究调查该方法的重测信度。我们先前报道了通过脑电图(EEG)测量的ASSR可靠性,达到40 Hz幅度调制的白噪声和点击火车刺激。本研究的目的是(a)评估MEG量测的ASSR对40 Hz调幅白噪声和咔嗒声刺激的可靠性,以及(b)比较MESR的MEG和EEG量度之间的重测信度,以前没有进行过调查。另外,通过比较对白噪声和点击火车刺激的响应,评估了刺激参数选择对可靠性的影响。在17位健康成年人中,在大约相隔一周的疗程中评估了重测信度。在每个学习日,参加者在分别的MEG和EEG录音中完成了两项被动听音任务(白噪声和点击火车刺激)。在源空间投影之后,评估了诱发功率和试验间相干性(ITPC)的会话间相关性。总体而言,MEG测得的ASSR在各个疗程之间显着相关(p <0.05,经FDR校正),表明可接受的重测信度。结果表明,与诱发反应相比,ITPC的反应重现性更高;与白噪声刺激相比,点击火车的响应重现性更高,尽管有待进一步研究。 MEG和EEG措施之间未观察到可靠性的显着差异,表明它们同样可靠。这项工作支持在重复性措施的临床干预中将ASSR用作生物标记物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号