首页> 美国卫生研究院文献>Journal of Cerebral Blood Flow Metabolism >Kinetic evaluation and test–retest reproducibility of11CUCB-J a novel radioligand for positron emission tomographyimaging of synaptic vesicle glycoprotein 2A in humans
【2h】

Kinetic evaluation and test–retest reproducibility of11CUCB-J a novel radioligand for positron emission tomographyimaging of synaptic vesicle glycoprotein 2A in humans

机译:动力学评估和重测重现性11C UCB-J一种用于正电子发射断层扫描的新型放射性配体突触小泡糖蛋白2A的成像

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Synaptic vesicle glycoprotein 2A (SV2A) is ubiquitously present in presynaptic terminals. Here we report kinetic modeling and test–retest reproducibility assessment of the SV2A positron emission tomography (PET) radioligand [11C]UCB-J in humans. Five volunteers were examined twice on the HRRT after bolus injection of [11C]UCB-J. Arterial blood samples were collected for measurements of radiometabolites and free fraction. Regional time–activity curves were analyzed with 1-tissue (1T) and 2-tissue (2T) compartment models to estimate volumes of distribution (VT). Parametric maps were generated using the 1T model. [11C]UCB-J metabolized fairly quickly, with parent fraction of 36 ± 13% at 15 min after injection. Plasma free fraction was 32 ± 1%. Regional time–activity curves displayed rapid kinetics and were well described by the 1T model, except for the cerebellum and hippocampus. VT values estimated with the 2T model were similar to 1T values. Parametric maps were of high quality and VT values correlated well with time activity curve (TAC)-based estimates. Shortening of acquisition time from 120 min to60 min had a negligible effect on VT values. Themean absolute test–retest reproducibility for VT was3–9% across regions. In conclusion, [11C]UCB-J exhibited excellentPET tracer characteristics and has potential as a general purpose tool formeasuring synaptic density in neurodegenerative disorders.
机译:突触前囊泡中普遍存在突触囊泡糖蛋白2A(SV2A)。在这里,我们报告了人体SV2A正电子发射断层扫描(PET)放射性配体[ 11 C] UCB-J的动力学建模和重测重现性评估。推注[ 11 C] UCB-J后,对5名志愿者进行了HRRT两次检查。收集动脉血样品以测量放射性代谢产物和游离分数。用1组织(1T)和2组织(2T)隔室模型分析了区域时间-活动曲线,以估计分布量(VT)。参数图是使用1T模型生成的。 [ 11 C] UCB-J代谢相当快,注射后15分钟时母体比例为36±13%。无血浆分数为32±1%。区域时间-活动曲线显示出快速的动力学,并且由1T模型很好地描述了,小脑和海马除外。用2T模型估算的VT值类似于1T值。参数图质量很高,VT值与基于时间活动曲线(TAC)的估计值相关性很好。采集时间从120分钟缩短至60分钟对VT值的影响可忽略不计。的VT的平均绝对值-重测重现性为跨地区的3–9%。总之,[ 11 C] UCB-J表现出优异的PET示踪剂的特性,有潜力作为通用工具测量神经变性疾病中的突触密度。

著录项

相似文献

  • 外文文献
  • 中文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号