首页> 美国卫生研究院文献>Frontiers in Physiology >Cardiovascular and Muscular Consequences of Work-Matched Interval-Type of Concentric and Eccentric Pedaling Exercise on a Soft Robot
【2h】

Cardiovascular and Muscular Consequences of Work-Matched Interval-Type of Concentric and Eccentric Pedaling Exercise on a Soft Robot

机译:工作匹配的间隔时间类型的软机器人上的同心和偏心踏板运动的心血管和肌肉后果

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Eccentric types of endurance exercise are an acknowledged alternative to conventional concentric types of exercise rehabilitation for the cardiac patient, because they reduce cardiorespiratory strain due to a lower metabolic cost of producing an equivalent mechanical output. The former contention has not been tested in a power- and work-matched situation of interval-type exercise under identical conditions because concentric and eccentric types of exercise pose specific demands on the exercise machinery, which are not fulfilled in current practice. Here we tested cardiovascular and muscular consequences of work-matched interval-type of leg exercise (target workload of 15 sets of 1-min bipedal cycles of knee extension and flexion at 30 rpm with 17% of maximal concentric power) on a soft robotic device in healthy subjects by concomitantly monitoring respiration, blood glucose and lactate, and power during exercise and recovery. We hypothesized that interval-type of eccentric exercise lowers strain on glucose-related aerobic metabolism compared to work-matched concentric exercise, and reduces cardiorespiratory strain to levels being acceptable for the cardiac patient. Eight physically active male subjects (24.0 years, 74.7 kg, 3.4 L O2 min−1), which power and endurance performance was extensively characterized, completed the study, finalizing 12 sets on average. Average performance was similar during concentric and eccentric exercise (p = 0.75) but lower than during constant load endurance exercise on a cycle ergometer at 75% of peak aerobic power output (126 vs. 188 Watt) that is recommended for improving endurance capacity. Peak oxygen uptake (−17%), peak ventilation (−23%), peak cardiac output (−16%), and blood lactate (−37%) during soft robotic exercise were lower during eccentric than concentric exercise. Glucose was 8% increased after eccentric exercise when peak RER was 12% lower than during concentric exercise. Muscle power and RFD were similarly reduced after eccentric and concentric exercise. The results highlight that the deployed interval-type of eccentric leg exercise reduces metabolic strain of the cardiovasculature and muscle compared to concentric exercise, to recommended levels for cardio-rehabilitation (i.e., 50–70% of peak heart rate). Increases in blood glucose concentration indicate that resistance to contraction-induced glucose uptake after the deployed eccentric protocol is unrelated to muscle fatigue.
机译:对于心脏病患者,偏心类型的耐力运动是常规同心类型的运动康复的公认替代产品,因为它们可降低心肺劳损,这是因为产生同等机械输出的代谢成本较低。前者的争论尚未在相同条件下的间歇式锻炼的动力和工作匹配情况下进行过测试,因为同心和偏心锻炼对健身器材提出了特殊要求,而当前的实践并未满足这一要求。在这里,我们在软机器人设备上测试了与工作相配的腿部锻炼(在15 rpm的条件下,以30 rpm的速度进行30分钟的膝盖伸展和屈曲的1分钟双足双足运动的15组目标工作量)的心血管和肌肉后果:在健康受试者中,通过监测运动,恢复过程中的呼吸,血糖和乳酸以及力量来进行健康检查。我们假设与工作匹配的同心运动相比,间歇性的离心运动可降低与葡萄糖相关的有氧代谢的压力,并将心肺压力降低至心脏病患者可接受的水平。八项体育锻炼的男性受试者(24.0岁,74.7千克,3.4 L O2分钟 -1 )被广泛表征,完成了研究,平均完成了12套运动。在同心和偏心运动中,平均表现相似(p = 0.75),但在有氧运动峰值功率输出的75%(126与188瓦)上的循环测功机上,其平均表现却不如此,建议提高耐力。在偏心锻炼中,软机器人锻炼期间的峰值摄氧量(−17%),峰值通气量(−23%),峰值心输出量(−16%)和血乳酸(−37%)低于同心运动。当峰值RER比同心运动时低12%时,偏心运动后血糖增加8%。离心运动和同心运动后,肌肉力量和RFD的下降也相似。结果表明,与同心运动相比,部署的间隔时间的偏心腿运动可减少心血管系统和肌肉的代谢劳损,达到建议的心脏康复水平(即峰值心率的50-70%)。血糖浓度增加表明,在部署的离心方案后,对收缩诱导的葡萄糖摄取的抵抗力与肌肉疲劳无关。

著录项

相似文献

  • 外文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号