首页> 美国卫生研究院文献>other >Blood Quality Diagnostic Device Detects Storage Differences Between Donors
【2h】

Blood Quality Diagnostic Device Detects Storage Differences Between Donors

机译:血液质量诊断设备可检测捐赠者之间的存储差异

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In 2013, nearly 15 million units of banked blood were transfused in the United States alone. Blood shortages are expected to increase globally. Donated blood is not equal due to differences in quality and deterioration rate. There are no methods to detect time-dependent biochemical and biophysical changes of RBCs or the deterioration rate of donated RBCs. Nine randomly selected RBC units collected by the San Diego Blood Bank were examined for inter-donor variability over six weeks of storage. In vitro RBC quality was assessed weekly by conventional biochemical tests including free Hb, K+, ATP, P50, 2,3 DPG, lactate, and pH. Deformability was measured via cell filtration. Briefly, the RBC suspension (10% Hct), was forced through a 5.0μm pore membrane (106 mm2) at various flow rates. No inter-donor variability in biochemical or mechanical parameters was observed at baseline. Inter-donor variability in biochemical properties (free Hb, K+, ATP, P50, 2,3 DPG, lactate, and pH) was observed after 14 days of storage. However, significant differences from baseline in RBC mechanical properties (i.e. filterability) were observed as early as 7 days into storage at the lowest flow rates and after 28 days of storage at all flow rates. There was a net decrease in filterability over time for all donors, but the rate at which filterability decreased (i.e. deterioration rates) was different when comparing individual donors. Changes in all biochemical parameters were significant different between donors. These data suggest that filterability is more sensitive to changes in blood quality than conventional biochemical parameters.
机译:2013年,仅在美国就输了近1500万单位的储备血液。预计全球的血液短缺将加剧。由于质量和恶化率的差异,捐献的血液不相等。没有方法来检测随时间变化的红细胞的生化和生物物理变化或捐赠的红细胞的退化率。在储存的六周内,检查了圣地亚哥血液银行收集的9个随机选择的RBC单位的供体间变异性。每周通过常规生化测试评估体外RBC的质量,包括游离Hb,K +,ATP,P50、2,3 DPG,乳酸和pH值。通过细胞过滤测量可变形性。简而言之,以各种流速迫使RBC悬浮液(10%Hct)穿过5.0μm的孔膜(106 mm 2 )。基线时未观察到供体间生化或机械参数的变异性。储存14天后,观察到生物化学性质(游离Hb,K +,ATP,P50、2,3 DPG,乳酸和pH)的供体间变异性。然而,早在以最低流速储存7天后和在所有流速储存28天后,观察到RBC机械性能(即可过滤性)均与基线有显着差异。所有供体的可过滤性都随着时间的推移而净下降,但是当比较各个供体时,可过滤性下降的速率(即退化率)是不同的。供体之间所有生化参数的变化均存在显着差异。这些数据表明,过滤性比常规生化参数对血液质量的变化更为敏感。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号