首页> 美国卫生研究院文献>other >Optical Properties of Meloxicam in the Far-Infrared Spectral Region
【2h】

Optical Properties of Meloxicam in the Far-Infrared Spectral Region

机译:美洛昔康在远红外光谱区的光学性质

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

One of the most commonly used nonsteroidal anti-inflammatory active pharmaceutical ingredient called Meloxicam has been characterized spectroscopically both by Terahertz (THz) time domain spectroscopy (THz-TDS) and by Fourier Transform Infrared (FTIR) spectroscopy in far-IR regions of electromagnetic spectrum; 0.2 THz to 20 THz. While many relatively sharp features are observed in the far-IR range between 2 THz to 20 THz as expected for being an organic substance, very distinct and relatively strong absorption bands are also observed at 1.00, 1.66, 2.07 and 2.57 THz in the THz range. These well separated, defined, and fairly strong spectral features can be used for discrimination and quantification of Meloxicam in drug analysis. Frequency dependent refractive index of the drug was determined in a range of 0.2 THz and 2.7 THz, where an almost constant index was observed with an average index of 1.75. Powder XRD, and solid-state Density Functional Theory (SS-DFT) calculations were utilized to determine the crystalline form of the Meloxicam sample in its enolic crystalline form. Single molecule DFT calculations were also performed in all four possible structures of Meloxicam. In addition, the capability of THz waves transmission through common packaging materials is demonstrated for possibility of future on-site analysis. The results suggest that drug analysis will be possible to perform not only at every stage of manufacturing without destruction but also directly at the shelf of a market after development of portable THz technologies.
机译:最常用的非甾体抗炎活性药物成分之一美洛昔康已通过太赫兹(THz)时域光谱(THz-TDS)和傅立叶变换红外(FTIR)光谱在电磁光谱的远红外区域进行了光谱表征; 0.2 THz至20 THz尽管在2 THz至20 THz的远红外范围内观察到许多相对尖锐的特征,这是有机物,但在THz范围内的1.00、1.66、2.07和2.57 THz处也观察到了非常明显且相对较强的吸收带。 。这些分离得很好,定义清晰且相当强的光谱特征可用于美洛昔康在药物分析中的鉴别和定量。在0.2 THz和2.7 THz的范围内确定药物的频率依赖性折射率,其中观察到几乎恒定的折射率,平均折射率为1.75。粉末XRD和固态密度泛函理论(SS-DFT)计算用于确定Meloxicam样品的结晶形式(呈烯醇状)。还对美洛昔康的所有四个可能结构进行了单分子DFT计算。此外,还证明了太赫兹波通过普通包装材料的传输能力,以备将来进行现场分析时使用。结果表明,药物分析不仅可以在制造的每个阶段进行而不会受到破坏,而且在便携式THz技术发展之后也可以直接在市场上进行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号