For CyberKnife-mediated prostate cancer treatment, a tumour-tracking approach is applied to correct the target location by acquiring X-ray images of implanted fiducial markers intermittently. This study investigated the dosimetric impact of intra-fraction prostate motion during CyberKnife treatment. We retrospectively analyzed 16 patients treated using the CyberKnife (35 Gy delivered in five fractions). Using log files of recorded prostate motion, the intra-fraction prostate motion was simulated. We defined the worst-case intra-fraction prostate motion as the difference between pre- and post-deviation on log files and shifted structure sets according to the corresponding offsets for each beam. The dose–volume indices were calculated and compared with the original plan in terms of clinical target volume (CTV), planning target volume (CTV plus a 2-mm margin), rectum, bladder, and urethra. Prostate motions of >3, >5, and >10 mm were observed for 31.3, 9.1, and 0.5% of the 1929 timestamps, respectively. Relative differences between the simulated and original plans were mostly less than 1%. Although significant decreases were observed in D50% and D98% of the target, absolute dose differences were <0.1 Gy compared with the planned dose. The dosimetric impact of intra-fraction prostate motion may be small even with longer treatment durations, indicating that the tumour tracking using the CyberKnife could be a robust system for examining prostate motion.
机译:对于射波刀介导的前列腺癌治疗,采用肿瘤跟踪方法,通过间歇性获取植入的基准标记的X射线图像来校正目标位置。这项研究调查了射波刀治疗期间小剂量前列腺运动的剂量学影响。我们回顾性分析了使用电子刀治疗的16例患者(35 Gy分五部分递送)。使用记录的前列腺运动的日志文件,模拟了小部分内前列腺运动。我们将最坏情况下的小段内前列腺运动定义为日志文件和根据每个波束的相应偏移量偏移的结构集上的偏移前后之间的差异。计算剂量-体积指数,并将其与原始计划进行比较,包括临床目标量(CTV),计划目标量(CTV加2 mm边缘),直肠,膀胱和尿道。在1929年的时间戳中,分别有31.3、9.1和0.5%的前列腺运动> 3,> 5和> 10 mm。模拟计划和原始计划之间的相对差异通常小于1%。尽管在目标的D50%和D98%处观察到显着降低,但与计划剂量相比,绝对剂量差异<0.1 Gy。即使使用更长的治疗时间,小剂量内前列腺运动的剂量学影响也可能很小,这表明使用射波刀追踪肿瘤可能是检查前列腺运动的可靠系统。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号