首页> 美国卫生研究院文献>other >Full Band Spectra Analysis of Gait Acceleration Signals for Peripheral Arterial Disease Patients
【2h】

Full Band Spectra Analysis of Gait Acceleration Signals for Peripheral Arterial Disease Patients

机译:外周动脉疾病患者步态加速信号的全谱分析

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Peripheral arterial disease (PAD) is an artherosclerotic occlusive disorder of distal arteries, which can give rise to the intermittent claudication (IC) phenomenon, i.e., limb pain and necessity to stop. PAD patients with IC have altered their gait, increasing the fall risk. Several gait analysis works have studied acceleration signals (from sensors) to characterize the gait. One common technique is spectral analysis. However, this approach mainly uses dominant frequency (fd) to characterize gait patterns, and in a narrow spectral band, disregarding the full spectra information. We propose to use a full band spectral analysis (up to 15 Hz) and the fundamental frequency (f0) in order to completely characterize gait for both control subjects and PAD patients. Acceleration gait signals were recorded using an acquisition equipment consisting of four wireless sensor nodes located at ankle and hip height on both sides. Subjects had to walk, free-fashion, up to 10 min. The analysis of the periodicity of the gait acceleration signals, showed that f0 is statistically higher (p < 0.05) in control subjects (0.9743 ± 0.0716) than in PAD patients (0.8748 ± 0.0438). Moreover, the spectral envelope showed that, in controls, the power spectral density distribution is higher than in PAD patients, and that the power concentration is hither around the fd. In conclusion, full spectra analysis allowed to better characterize gait in PAD patients than classical spectral analysis. It allowed to better discriminate PAD patients and control subjects, and it also showed promising results to assess severity of PAD.
机译:周围动脉疾病(PAD)是远端动脉的动脉粥样硬化闭塞性疾病,可引起间歇性lau行(IC)现象,即肢体疼痛和必须停止。患有IC的PAD患者改变了步态,增加了跌倒的风险。一些步态分析工作已经研究了来自传感器的加速度信号以表征步态。一种常见的技术是光谱分析。但是,这种方法主要使用主频(fd)来表征步态模式,并且在狭窄的光谱带中忽略了整个光谱信息。我们建议使用全频带频谱分析(最高15 Hz)和基本频率(f0),以完全表征对照组和PAD患者的步态。使用由四个无线传感器节点组成的采集设备记录加速度步态信号,该无线传感器节点位于脚踝和臀部的两侧。受试者必须自由行走最多10分钟。步态加速信号的周期性分析表明,对照组的受试者(0.9743±0.0716)的f0在统计学上高于PAD患者(0.8748±0.0438)的(p <0.05)。此外,频谱包络表明,在对照组中,功率谱密度分布高于PAD患者,并且功率密度在fd附近。总之,与经典光谱分析相比,全光谱分析可以更好地表征PAD患者的步态。它可以更好地区分PAD患者和对照组,并且在评估PAD严重性方面也显示出令人鼓舞的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号