NEMA Performance Evaluation of CareMiBrain dedicated brain PET and Comparison with the whole-body and dedicated brain PET systems

机译:CareMiBrain专用大脑PET的NEMA性能评估以及与全身和专用大脑PET系统的比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

This article presents system performance studies of the CareMiBrain dedicated brain PET according to NEMA NU 2-2012 (for whole-body PETs) and NU 4-2008 (for preclinical PETs). This scanner is based on monolithic LYSO crystals coupled to silicon photomultipliers. The results obtained for both protocols are compared with current commercial whole body PETs and dedicated brain PETs found in the literature. Spatial resolution, sensitivity, NECR and scatter-fraction are characterized with NEMA standards, as well as an image quality study. A customized image quality phantom is proposed as NEMA phantoms do not fulfil the necessities of dedicated brain PETs. The full-width half maximum of the radial/tangential/axial spatial resolution of CareMiBrain reconstructed with FBP at 10 and 100 mm from the system center were, respectively, 1.87/1.68/1.39 mm and 1.86/1.91/1.40 mm (NU 2-2012) and 1.58/1.45/1.40 mm and 1.64/1.66/1.44 mm (NU 4-2008). Peak NECR was 49 kcps@287 MBq with a scatter fraction of 48% using NU 2-2012 phantom. The sensitivity was 13.82 cps/kBq at the center of the FOV (NU 2-2012) and 10% (NU 4-2008). Contrast recovery coefficients for customizing image quality phantom were 0.73/0.78/1.14/1.01 for the 4.5/6/9/12 mm diameter rods. The performance characteristics of CareMiBrain are at the top of the current technologies for PET systems. Dedicated brain PET systems significantly improve spatial resolution and sensitivity, but present worse results in count rate measurements and scatter-fraction tests. As for the comparison of preclinical and clinical standards, the results obtained for solid and liquid sources were similar.
机译:本文介绍了根据NEMA NU 2-2012(用于全身PET)和NU 4-2008(用于临床前PET)对CareMiBrain专用大脑PET的系统性能研究。该扫描仪基于与硅光电倍增管耦合的单片LYSO晶体。将两种方案获得的结果与文献中发现的当前商用全身PET和专用脑部PET进行比较。使用NEMA标准以及图像质量研究来表征空间分辨率,灵敏度,NECR和散射分数。提出了定制的图像质量体模,因为NEMA体模不能满足专用大脑PET的需要。用FBP在距系统中心10 10和100 mm处重建的CareMiBrain的径向/切向/轴向空间分辨率的半峰全宽分别为1.87 / 1.68 / 1.39 mm和1.86 / 1.91 / 1.40 mm(NU 2- 2012)和1.58 / 1.45 / 1.40 mm和1.64 / 1.66 / 1.44 mm(NU 4-2008)。使用NU 2-2012幻象,峰值NECR为49 kcps @ 287 MBq,散射率为48%。灵敏度在FOV(NU 2-2012)和10%(NU 4-2008)中心处为13.82 cps / kBq。对于直径为4.5 / 6/9 / 12mm的棒,用于定制图像质量体模的对比度恢复系数为0.73 / 0.78 / 1.14 / 1.01。 CareMiBrain的性能特征在PET系统的当前技术中居于首位。专用的大脑PET系统显着提高了空间分辨率和灵敏度,但在计数率测量和散射分数测试中却显示出较差的结果。至于临床前和临床标准的比较,固体和液体来源的结果相似。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号