We present an analytical and experimental study of split shape dose calculation correction by adjusting the position of the round leaf end position in an intensity‐modulated radiation therapy treatment planning system. The precise light field edge position (Xtang.p) was derived from 50% of the central axis dose created by nominal light field using geometry and mathematical methods. Leaf position (Xmlc.p), defined in the treatment planning system for monitor unit calculation, could be derived from Xtang.p. Offset (correction) could be obtained by the position corresponding to 50% of the central axis dose minus the Xmlc.p position. For SSD from 90 cm to 120 cm at 6 MV and 10 MV, the 50% dose position was located outside of Xmlc,p in the MLC leaf position range of + 8 cm to ‐8 cm, where the offset correction positively increased, whereas the offset correction negatively increased when the MLC leaf position was in the range of ‐12 cm to ‐8 cm and + 20 cm to + 8 cm when the 50% position was located inside Xmlc,p. The monitor unit calculation could provide underdosage or overdosage of 7.5% per mm without offset correction. Calibration could be performed at a certain SSD to fit all SSD offset corrections. With careful measurement and an accurate offset correction, it is possible to achieve the dose calculation with 0.5% error for the adjusted MLC leaf edge location in the treatment planning system.PACS number: 87.53.Tf, 87.55.x, 87.55.D, 87.55.dk
机译:我们通过调整强度调制放射治疗计划系统中圆形叶片末端位置的位置,对裂形剂量计算校正进行了分析和实验研究。精确的光场边缘位置(Xtang.p)是使用几何和数学方法从标称光场产生的中心轴剂量的50%得出的。在处理计划系统中定义的用于监视单位计算的叶位置(Xmlc.p)可以从Xtang.p派生。偏移(校正)可以通过对应于中心轴剂量的50%的位置减去Xmlc.p位置来获得。对于在6 MV和10 MV时从90 cm到120 cm的SSD,50%剂量位置位于Xmlc,p以外的MLC叶位置范围+8 cm至-8 cm,其中偏移量校正正增加,而当MLC叶片位置在Xmlc,p内时,当MLC叶片位置在‐12 cm至‐8 cm和+20 rangecm至+8 cm的范围内时,偏移校正会负向增加。监控器的计算可以提供每毫米7.5%的不足或过量,而无需偏移校正。可以在某个SSD上执行校准以适合所有SSD偏移校正。通过仔细的测量和精确的偏移校正,可以在治疗计划系统中针对调整后的MLC叶边缘位置实现0.5%误差的剂量计算.PACS编号:87.53.Tf,87.55.x,87.55.D,87.55 .dk

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号