The purpose of this study was to evaluate the applicator‐guided volumetric‐modulated arc therapy (AGVMAT) solution as an alternative to high‐dose‐rate brachytherapy (HDR‐BRT) treatment of the vaginal vault in patients with gynecological cancer (GC). AGVMAT plans for 51 women were developed. The volumetric scans used for plans were obtained with an implanted CT‐compatible vaginal cylinder which provides spatial registration and immobilization of the gynecologic organs. Dosimetric and radiobiological comparisons for planning target volume (PTV) and organs at risk (OARs) were performed by means of a dose‐volume histogram (DVH), equivalent uniform dose (EUD), and local tumor control probability (LTCP). In addition, the integral dose and the overall delivery time, were evaluated. The HDR‐BRT averages of EUD and minimum LTCP were significantly higher than those of AGVMAT. Doses for the OARs were comparable for the bladder and sigmoid, while, although HDR‐BRT was able to better spare the bowel, AGVMAT provided a significant reduction of d2cc, d1cc, and dmax (p  0.01) for the rectum. AGVMAT integral doses were higher than HDR‐BRT with low values in both cases. Delivery times were about two or three times higher for HDR‐BRT with respect to the single arc technique (AGVMAT1) and dual arc technique (AGVMAT2), respectively. The applicator‐guided volumetric‐modulated arc therapy seems to have the potential of improving rectum avoidance. However, brachytherapy improves performance in terms of PTV coverage, as demonstrated by a greater EUD and better LTCP curves.PACS number: 87
机译:这项研究的目的是评估妇科癌(GC)患者阴道贴膜器的高剂量率近距离放射治疗(HDR-BRT)的替代方案,以涂药器引导的容积调制弧光治疗(AGVMAT)解决方案。制定了针对51名妇女的AGVMAT计划。用于计划的体积扫描是通过植入CT兼容的阴道圆柱体获得的,该圆柱体提供了妇科器官的空间定位和固定。通过剂量-体积直方图(DVH),当量均匀剂量(EUD)和局部肿瘤控制概率(LTCP)对计划目标体积(PTV)和高危器官(OARs)进行剂量和放射生物学比较。另外,评估了积分剂量和总递送时间。 EUD和最小LTCP的HDR-BRT平均值明显高于AGVMAT。 OARs的剂量与膀胱和乙状结肠相当,尽管HDR-BRT能够更好地排便,但AGVMAT显着减少了d2cc,d1cc和dmax(p <0.01)。两种情况下,AGVMAT积分剂量均高于HDR-BRT,且数值较低。相对于单弧技术(AGVMAT1)和双弧技术(AGVMAT2),HDR-BRT的交货时间分别高出大约2或3倍。涂药指导下的容积调制电弧治疗似乎有可能改善避免直肠的潜力。但是,近距离疗法可以提高PTV的覆盖范围,这可以通过更大的EUD和更好的LTCP曲线来证明.PACS数:87