首页> 美国卫生研究院文献>Journal of Applied Clinical Medical Physics >Perturbation of TG‐43 parameters of the brachytherapy sources under insufficient scattering materials
【2h】

Perturbation of TG‐43 parameters of the brachytherapy sources under insufficient scattering materials

机译:在散射物质不足的情况下近距离放射治疗源的TG-43参数扰动

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

In the recommendations of Task Group #43 from American Association of Physicists in Medicine (AAPM TG43), methods of brachytherapy source dosimetry are recommended, under full scattering conditions. However, in actual brachytherapy procedures, sources may not be surrounded by full scattering tissue in all directions. Clinical examples include high‐dose‐rate (HDR) brachytherapy of the breast or low‐dose‐rate (LDR) brachytherapy of ocular melanoma using eye plaque treatment with  125I and  103Pd. In this work, the impact of the missing tissue on the TG‐43–recommended dosimetric parameters of different brachytherapy sources was investigated. The impact of missing tissue on the TG‐43–recommended dosimetric parameters of  137Cs,  192Ir, and  103Pd brachytherapy sources was investigated using the MCNP5 Monte Carlo code. These evaluations were performed by placing the sources at different locations inside a 30 × 30 × 30 cm3 cubical water phantom and comparing the results with the values of the source located at the center of the phantom, which is in a full scattering condition. The differences between the thickness of the overlying tissues for different source positions and the thickness of the overlying tissue in full scattering condition is referred to as missing tissue. The results of these investigations indicate that values of the radial dose function and 2D anisotropy function vary as a function of the thickness of missing tissue, only in the direction of the missing tissue. These changes for radial dose function were up to 5%, 11%, and 8% for  137Cs,  192Ir, and  103Pd, respectively. No significant changes are observed for the values of the dose rate constants. In this project, we have demonstrated that the TG‐43 dosimetric parameters may only change in the directions of the missing tissue. These results are more practical than the published data by different investigators in which a symmetric effect of the missing tissue on the dosimetric parameters of brachytherapy source are being considered, regardless of the implant geometry in real clinical cases.PACS number: 87.53.JW
机译:在美国医学物理学会(AAPM TG43)的第43号任务组的建议中,建议在完全散射的条件下进行近距离放射治疗的剂量法。但是,在实际的近距离放射治疗程序中,放射源可能不会在各个方向上都被完全散布的组织所包围。临床实例包括使用 125 I和 103 钯在这项工作中,研究了缺失组织对不同近距离放射治疗源的TG-43推荐剂量参数的影响。使用以下方法研究了组织缺失对TG-43推荐的 137 Cs, 192 Ir和 103 Pd近距离放射治疗源的剂量参数的影响MCNP5蒙特卡洛代码。这些评估是通过将光源放置在30×30×30 cm 3 立方水体模中的不同位置并将结果与​​位于体模中心的光源值进行比较来进行的在完全散射的条件下。对于不同源位置,上覆组织的厚度与完全散射状态下上覆组织的厚度之间的差异称为缺失组织。这些研究的结果表明,径向剂量函数和2D各向异性函数的值仅在缺失组织的方向上随缺失组织的厚度而变化。对于radial 137 Cs, 192 Ir和 103 Pd,径向剂量函数的这些变化分别高达5%,11%和8%,分别。剂量率常数的值没有观察到显着变化。在该项目中,我们证明了TG‐43剂量参数仅可能在缺失组织的方向上发生变化。这些结果比不同研究者发表的数据更为实用,在研究中,考虑了缺失组织对近距离放射源剂量参数的对称影响,而与实际临床情况下的植入物几何形状无关。PACS编号:87.53.JW

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号