Treatment of the wrong body part due to incorrect setup is among the leading types of errors in radiotherapy. The purpose of this paper is to report an efficient automatic patient safety system (PSS) to prevent gross setup errors. The system consists of a pair of charge‐coupled device (CCD) cameras mounted in treatment room, a single infrared reflective marker (IRRM) affixed on patient or immobilization device, and a set of in‐house developed software. Patients are CT scanned with a CT BB placed over their surface close to intended treatment site. Coordinates of the CT BB relative to treatment isocenter are used as reference for tracking. The CT BB is replaced with an IRRM before treatment starts. PSS evaluates setup accuracy by comparing real‐time IRRM position with reference position. To automate system workflow, PSS synchronizes with the record‐and‐verify (R&V) system in real time and automatically loads in reference data for patient under treatment. Special IRRMs, which can permanently stick to patient face mask or body mold throughout the course of treatment, were designed to minimize therapist's workload. Accuracy of the system was examined on an anthropomorphic phantom with a designed end‐to‐end test. Its performance was also evaluated on head and neck as well as abdominalpelvic patients using cone‐beam CT (CBCT) as standard. The PSS system achieved a seamless clinic workflow by synchronizing with the R&V system. By permanently mounting specially designed IRRMs on patient immobilization devices, therapist intervention is eliminated or minimized. Overall results showed that the PSS system has sufficient accuracy to catch gross setup errors greater than 1 cm in real time. An efficient automatic PSS with sufficient accuracy has been developed to prevent gross setup errors in radiotherapy. The system can be applied to all treatment sites for independent positioning verification. It can be an ideal complement to complex image‐guidance systems due to its advantages of continuous tracking ability, no radiation dose, and fully automated clinic workflow.PACS number: 87.55.Qr
机译:由于放疗不正确而导致的身体部位错误的治疗是放射治疗错误的主要类型。本文的目的是报告一种有效的自动患者安全系统(PSS),以防止出现总设置错误。该系统由安装在治疗室中的一对电荷耦合设备(CCD)摄像机,固定在患者或固定设备上的单个红外反射标记(IRRM)以及一套内部开发的软件组成。用CT BB扫描患者,CT BB放置在靠近预期治疗部位的表面上。 CT BB相对于治疗等角点的坐标用作跟踪参考。在治疗开始之前,将CT BB替换为IRRM。 PSS通过将实时IRRM位置与参考位置进行比较来评估设置精度。为了自动执行系统工作流程,PSS实时与记录验证(R&V)系统同步,并自动加载参考数据以供治疗中的患者使用。特殊的IRRM可以在治疗过程中永久粘附在患者的口罩或身体霉菌上,旨在最大程度地减少治疗师的工作量。使用拟定的端到端测试在拟人模型上检查了系统的准确性。还使用锥形束CT(CBCT)作为标准对头颈部以及腹部骨盆患者进行了评估。通过与R&V系统同步,PSS系统实现了无缝的诊所工作流程。通过将特殊设计的IRRM永久安装在患者固定装置上,可以消除或减少治疗师的干预。总体结果表明,PSS系统具有足够的精度,可以实时捕获大于1厘米的总设置误差。已经开发出具有足够精度的有效自动PSS,以防止放射治疗中的总体设置错误。该系统可以应用于所有治疗部位,以进行独立的位置验证。它具有连续跟踪能力,无辐射剂量和全自动临床工作流程等优点,因此可以成为复杂图像引导系统的理想补充.PACS编号:87.55.Qr

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号