The purpose of this study is to investigate the interplay effect between dynamic MLC movement and tumor respiratory motion in volumetric‐modulated arc therapy (VMAT)‐based lung SBRT treatment delivered by the flattening filter‐free (FFF) beam of a Varian TrueBeam machine. Six lung cancer patients with tumor motions ranging between 0.5–1.6 cm were recruited in this study. All patients underwent 4D‐CT scan with audiocoaching. A two‐arc VMAT plan was retrospectively generated using Varian's Eclipse planning system for each patient. To explicitly describe the interplay effect, the contributions of each control point in the original static VMAT plans to each respiratory phase were calculated, and then ten new VMAT plans corresponding to different respiratory phases were generated and imported back into Eclipse planning system to calculate the radiation dose based on the CT images of related respiratory phase. An in‐house 4D dose calculation program with deformable registration capacity was used to calculate the accumulative 4D dose distribution of the targets. For all patients, the PTV coverage dropped significantly with increased respiratory motion amplitude. However, V100 and D90 of the GTV and GTV+5mm, which mimic the target with setup error of less than 5 mm, were either unchanged or slightly increased up to 1.2%, and the variations of their minimum doses were less than 3.2%. Our results indicated that for VMAT‐based lung SBRT treatment delivered by FFF beam of TrueBeam machine, the impact of interplay effects on target coverage is insignificant, as long as a sufficient margin was given.PACS number: 87.53.Ly
机译:这项研究的目的是研究在瓦里安TrueBeam机器的扁平无滤镜(FFF)光束提供的基于体积调制电弧疗法(VMAT)的肺SBRT治疗中动态MLC运动与肿瘤呼吸运动之间的相互作用。本研究招募了六名肿瘤运动范围在0.5-1.6 cm之间的肺癌患者。所有患者均接受了音频指导的4D-CT扫描。使用Varian的Eclipse规划系统为每位患者回顾性地生成了一个两弧VMAT计划。为了明确描述相互作用的影响,计算了原始静态VMAT计划中每个控制点对每个呼吸阶段的贡献,然后生成了十个与不同呼吸阶段相对应的新VMAT计划,然后将其导入Eclipse规划系统以计算辐射根据相关呼吸道的CT图像确定剂量。具有可变形注册能力的内部4D剂量计算程序用于计算目标的累积4D剂量分布。对于所有患者,随着呼吸运动幅度的增加,PTV覆盖率显着下降。但是,GTV的V100和D90以及 GTV + 5 mm ,它模仿了设定误差小于5毫米的目标,保持不变或略微增加至1.2%,最小剂量的变化小于3.2%。我们的结果表明,对于TrueBeam机器的FFF光束进行的基于VMAT的肺SBRT治疗,只要给出足够的余量,相互作用对靶标覆盖率的影响就不明显了.PACS数:87.53.Ly

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号