首页> 美国卫生研究院文献>Physiological Reports >Transcutaneous assessment of glomerular filtration rate in unanesthetized rats using a small animal imager: impact on arterial pressure heart rate and activity
【2h】

Transcutaneous assessment of glomerular filtration rate in unanesthetized rats using a small animal imager: impact on arterial pressure heart rate and activity

机译:使用小型动物成像仪经皮评估未麻醉大鼠的肾小球滤过率:对动脉压心率和活动的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Transcutaneous assessment of fluorescein isothiocyanate (FITC)‐sinistrin clearance using a small animal imager has recently been validated as an accurate method for the measurement of glomerular filtration rate (GFR) in freely moving rats. This technique involves a brief, light period of anesthesia during which the imager is adhered to the rat and FITC‐sinistrin is administered. The rat is then moved to an experimental chamber where it is housed unrestrained for a 2‐h data collection period. This study assessed the impact of the experimental protocol on mean arterial pressure (MAP), heart rate, and locomotor activity in adult Sprague Dawley rats using radiotelemetry given that anesthesia and stress are known to affect arterial pressure and kidney function. These data were compared with time‐equivalent measurements made in the same rats at rest. MAP was low following anesthesia, but increased within 15 min and remained stable thereafter. Heart rate was not affected by the GFR protocol. Locomotor activity increased following anesthesia before decreasing to relatively low levels during the final 75‐min, the approximate period from which GFR is calculated. Moreover, MAP, heart rate, and locomotor activity during the final 75‐min of the data collection period were not different to that observed during an equivalent time period at baseline. Taken together, our findings suggest that this recently developed minimally invasive procedure for the measurement of GFR in unanesthetized rats does not negatively impact arterial pressure, heart rate, or locomotor activity. Thus, it is likely to be a valuable implement for acquiring serial measurements of GFR in unanesthetized rats.
机译:最近已经验证了使用小型动物成像仪对异硫氰酸荧光素(FITC)-芥子苷的清除率进行皮下评估,作为测量自由移动大鼠肾小球滤过率(GFR)的准确方法。该技术涉及短暂的麻醉期,在此期间将成像仪粘附到大鼠上,并使用FITC-神经鞘内酯。然后将大鼠移至实验室,在2小时的数据收集时间内不受约束地将其收容。鉴于已知麻醉和压力会影响动脉压和肾功能,本研究使用放射遥测法评估了实验规程对成年Sprague Dawley大鼠平均动脉压(MAP),心率和运动活动的影响。将这些数据与在相同大鼠静止状态下进行的等效时间测量进行比较。麻醉后MAP较低,但在15分钟内升高,此后保持稳定。心率不受GFR协议的影响。麻醉后运动能力增加,然后在最后75分钟(即计算GFR的大致时间)内降低到相对较低的水平。此外,在数据收集期的最后75分钟内,MAP,心率和运动活动与在基线的相同时间段内观察到的无差异。综上所述,我们的发现表明,这种最近开发的用于在未麻醉的大鼠中测量GFR的微创程序不会对动脉压,心率或运动能力产生负面影响。因此,它可能是获得未麻醉大鼠的GFR连续测量值的有价值的工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号