首页> 美国卫生研究院文献>Journal of Applied Clinical Medical Physics >Validating kQ=1.0 assumption in TG51 with PTW 30013 farmer chamber for Varian TrueBeams 2.5 MV imaging beam
【2h】

Validating kQ=1.0 assumption in TG51 with PTW 30013 farmer chamber for Varian TrueBeams 2.5 MV imaging beam

机译:使用PTW 30013农夫室在TG51中验证kQ = 1.0假设是否适用于Varian TrueBeam的2.5 MV成像光束

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

AAPM Report 142 recommends and the State of Ohio requires that the imaging dose be quantified in radiotherapy applications. Using the TG51 dose calibration protocol for MV Imaging dose measurement requires knowledge of the kQ parameter for the beam quality and the ionization chamber type under investigation. The %dd(10)x of the Varian TrueBeam 2.5 MV imaging beam falls outside the range of the available data for the calculation of the kQ value. Due to the similarities of the 2.5 MV imaging beam and the 60Co beam, we and others made the assumption that kQ = 1.0 in TG51 calculations. In this study, we used the TG21 and TG51 calibration protocols in conjunction to validate that kQ = 1.0 for the 2.5 MV imaging beam using a PTW 30013 farmer chamber. Standard measurements for TG51 absolute dosimetry QA were performed at 100 cm SSD, 10 cm depth, 10 × 10 field size, delivering 100 Monitor Units to a waterproof Farmer Chamber (PTW TN30013) for both 2.5 and 6 MV. Both the TG21 and TG51 formalisms were used to calculate the dose to water per MU at dmax (Dw/MU) for the 6 MV beam. The calculated outputs were 1.0005 and 1.0004 cGy/MU respectively. The TG21 formalism was then used to calculate (Dw/MU) for the 2.5 MV imaging beam. This value was then used in the TG51 formalism to find kQ for the 2.5 MV imaging beam. A kQ value of 1.00 ± 0.01 was calculated for 2.5 MV using this method.
机译:AAPM报告142建议,俄亥俄州要求在放射治疗应用中对成像剂量进行量化。使用TG51剂量校准方案进行MV成像剂量测量需要了解有关光束质量和所研究电离室类型的kQ参数。 Varian TrueBeam 2.5 MV成像光束的%dd(10)x超出了用于计算kQ值的可用数据范围。由于2.5 MV成像光束和 60 Co光束的相似性,我们和其他人在TG51计算中假设kQ = 1.0。在这项研究中,我们结合使用了TG21和TG51校准协议,以验证使用PTW 30013农夫室的2.5 MV成像光束的kQ = 1.0。 TG51绝对剂量法QA的标准测量是在100 cm SSD,10 cm深度,10×10场大小下进行的,将100个监控器分别送入2.5 MV和6 MV的防水农夫舱(PTW TN30013)。 TG21和TG51形式均用于计算6 MV光束在dmax(Dw / MU)下每MU的水剂量。计算的输出分别为1.0005和1.0004 cGy / MU。然后使用TG21形式来计算2.5 MV成像光束的(Dw / MU)。然后将该值用于TG51形式中,以找到2.5 MV成像光束的kQ。使用该方法计算出2.5 MV的kQ值为1.00±0.01。

著录项

相似文献

  • 外文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号