Endobronchial brachytherapy (EBB) is an effective treatment for endobronchial tumors. However, bronchial toxicity caused by over-irradiation remains problematic. To decrease bronchial toxicity, we developed a source-centralizing applicator for EBB. The purpose of the present study was to assess the efficacy and safety of EBB with varying reference dose points according to the bronchial diameter, using a source-centralizing applicator. We reviewed 15 patients with endobronchial carcinoma who were treated with curative intent using a combination of external beam radiotherapy (EBRT) and high-dose-rate EBB between 2005 and 2014. During each EBB session, we used a source-centralizing applicator that maintained the source-delivering catheter in the center of the bronchial lumen. Reference dose points were 5–7 mm from the source axis, depending on the bronchial diameter. The median radiation doses of EBRT and EBB were 40 Gy in 20 fractions and 18 Gy in 3 fractions, respectively. The median observation period was 36 months. The 3-year overall survival, progression-free survival and local control rates were 79%, 77% and 100%, respectively. Grade 2 radiation pneumonitis was observed in two cases. Bronchial toxicities, such as hemoptysis or the symptoms of chronic bronchitis, were not observed. EBB with varying reference dose points according to bronchial diameter, using a source-centralizing applicator, is a promising procedure that may be effective for tumor elimination and reducing toxicity to the bronchial wall.
机译:支气管内近距离放射疗法(EBB)是支气管内肿瘤的有效治疗方法。但是,由过度照射引起的支气管毒性仍然存在问题。为了降低支气管毒性,我们开发了EBB的源头集中式涂抹器。本研究的目的是使用来源集中式涂药器,根据支气管直径评估不同参考剂量点的EBB的疗效和安全性。我们回顾了2005年至2014年间采用外照射治疗(EBRT)和高剂量EBB联合治疗的15例支气管内癌患者。气管导管位于支气管腔的中心。参考剂量点距源轴为5–7 mm,具体取决于支气管直径。 EBRT和EBB的中值辐射剂量分别为20馏分中的40 Gy和3馏分中的18 Gy。中位观察期为36个月。 3年总生存率,无进展生存率和局部控制率分别为79%,77%和100%。有2例观察到2级放射性肺炎。没有观察到支气管毒性,例如咯血或慢性支气管炎的症状。使用源集中式涂药器,根据支气管直径改变参考剂量点的EBB是一种有前途的方法,可能有效消除肿瘤并降低对支气管壁的毒性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号