This study aimed to quantify the intra-and inter-instrument reliability of the Actiwatch 4 accelerometer (AW4) in a mechanical setting. Twenty seven AW4 were attached to an isokinetic dynamometer and subjected to angular acceleration for 30 min at 50 deg/sec representing moderate intensity (MPA condition) and 200 deg/sec representing vigorous intensity (VPA condition), with a repeat trial conducted. Reliability was assessed using coefficient of variation (CV), absolute percent error (APE), and intraclass correlation coefficients (ICC). Mean AW4 activity counts displayed acceptable reliability according to CV in both conditions (ConMPA: CVintra = 4.6%, APEintra = 6.6%, CVinter = 6.4%, APEinter = 5.2%; ConVPA: CVintra = 3.9%, APEintra = 5.6%, CVinter = 5.9%, APEinter = 4.7%). When counts were re-categorised into minutes of MPA and VPA, lower CV values were observed (ConMPA: CVintra = 3.2%, APEintra = 4.5%, CVinter = 4.3%, APEinter = 3.2%; ConVPA: CVintra = 0.0%, APEintra = 0.0%, CVinter = 0.0%, APEinter = 0.0%). When activity counts were re-categorised as minutes of MVPA, excellent reliability was observed (CVintra, APEintra, CVinter, and APEinter = 0.0%) in both conditions. Mean AW4 activity counts exhibit reliability statistics comparable to other accelerometers. Reliability is improved when activity counts are re-categorised as time spent in MPA and VPA, with greatest reliability obtained when counts are recategorised as time spent in MVPA. As MVPA is the subcomponent of physical activity most associated with health benefits it would appear that the AW4 is reliable for measuring time spent in this health enhancing intensity category, at least from testing in a mechanical laboratory setting.
机译:这项研究旨在量化Actiwatch 4加速度计(AW4)在机械环境下仪器内部和仪器之间的可靠性。将二十七个AW4连接到等速测力计上,并在代表中等强度的50度/秒(MPA条件)和代表剧烈强度的200度/秒(VPA条件)下经受30分钟的角加速度,并进行了重复试验。使用变异系数(CV),绝对误差百分比(APE)和组内相关系数(ICC)评估可靠性。在两种情况下,平均AW4活性计数均显示出根据CV可接受的可靠性(ConMPA:CVintra = 4.6%,APEintra = 6.6%,CVinter = 6.4%,APEinter = 5.2%; ConVPA:CVintra = 3.9%,APEintra = 5.6%,CVinter = 5.9%,APEinter = 4.7%)。当将计数重新分类为MPA和VPA分钟时,观察到较低的CV值(ConMPA:CVintra = 3.2%,APEintra = 4.5%,CVinter = 4.3%,APEinter = 3.2%; ConVPA:CVintra = 0.0%,APEintra = 0.0%,CVinter = 0.0%,APEinter = 0.0%)。当将活动计数重新分类为MVPA分钟时,在两种情况下均观察到出色的可靠性(CVintra,APEintra,CVinter和AP​​Einter = 0.0%)。平均AW4活动计数显示出与其他加速度计相当的可靠性统计数据。将活动计数重新分类为在MPA和VPA中花费的时间时,可靠性得到了提高,当将计数重新分类为在MVPA中花费的时间时,可靠性得到了最大的提高。由于MVPA是身体活动的最重要组成部分,与健康益处最相关,因此看来AW4至少对于在机械实验室中的测试而言,可以可靠地测量在此健康增强强度类别中花费的时间。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号