首页> 美国卫生研究院文献>Bioscience Reports >Comprehensive assessment of cavernosography with 320-row dynamic volume CT versus conventional cavernosography in erectile dysfunction patients caused by venous leakage
【2h】

Comprehensive assessment of cavernosography with 320-row dynamic volume CT versus conventional cavernosography in erectile dysfunction patients caused by venous leakage

机译:与行常规海绵体彩超检查相比使用320排动态容积CT进行海绵体彩超检查对由静脉渗漏引起的勃起功能障碍患者的综合评估

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The present study aims to investigate and compare the diagnostic and prognostic value of cavernosography with 320-row dynamic volume computed tomography (DVCT) versus conventional cavernosography in men with erectile dysfunction (ED) caused by venous leakage. A total of 174 patients diagnosed with ED were enrolled and received cavernosography with 320-row DVCT (DVCT group) and conventional cavernosography scans (control group) respectively. The diagnosis, complications, and prognosis of patients were evaluated. The DVCT group provided high-resolution images with less processing and testing time, as well as lowered radiological agent and contrast agent compared with the control group. In the DVCT group, 89 patients who were diagnosed with venous ED had six various venous leakage, namely superficial venous leakage, profundus venous leakage, the mixed type, cavernosal venous leakage, crural venous leakage, and also venous leakage between the penis and urethra cavernosum (9, 21, 32, 6, 18, and 3 cases respectively). Similarly, 74 patients out of the 81 who suffered from venous ED were classified to have superficial venous leakage (11), profundus venous leakage (14), the mixed type venous leakage (26), and middle venous leakage (23). Six out of 25 patients in the DVCT group, had improvements in ED while the remaining 19 achieved full erectile function recovery with no penile fibrosis and erectile pain. Cavernosography with 320-row DVCT is a reliable system that can be used to diagnose ED caused by venous leakage. This is especially useful in accurately determining the type of venous and allows for a better prognosis and direction of treatment.
机译:本研究旨在调查和比较320排动态容积计算机断层扫描(DVCT)与常规海绵体层成像术对由静脉渗漏引起的勃起功能障碍(ED)男性的海绵体层成像术的诊断和预后价值。共有174名被诊断为ED的患者入选并接受了320行DVCT的海绵体扫描(DVCT组)和常规的海绵体扫描(对照组)。评价患者的诊断,并发症和预后。 DVCT组与对照组相比,提供的高分辨率图像具有更少的处理和测试时间,并且降低了放射剂和造影剂。在DVCT组中,被诊断患有静脉ED的89例患者有6种不同的静脉渗漏,分别是浅表静脉渗漏,基底部静脉渗漏,混合型,海绵体静脉渗漏,cru部静脉渗漏以及阴茎和尿道海绵体之间的静脉渗漏。 (分别为9、21、32、6、18和3例)。同样,在81例患有静脉ED的患者中,有74例被分类为浅表静脉渗漏(11),眼底静脉渗漏(14),混合型静脉渗漏(26)和中静脉渗漏(23)。 DVCT组的25位患者中有6位的ED改善,其余19位的勃起功能完全恢复,没有阴茎纤维化和勃起疼痛。带320行DVCT的海绵体造影是一种可靠的系统,可用于诊断由静脉渗漏引起的ED。这在准确确定静脉类型方面特别有用,并可以改善预后和治疗方向。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号