首页> 美国卫生研究院文献>Journal of Korean Medical Science >Reference Values for the Pulmonary Function of Korean Adults Using the Data of Korea National Health and Nutrition Examination Survey IV (2007-2009)
【2h】

Reference Values for the Pulmonary Function of Korean Adults Using the Data of Korea National Health and Nutrition Examination Survey IV (2007-2009)

机译:使用韩国国民健康与营养检查问卷调查IV(2007-2009)数据得出的韩国成年人肺功能参考值

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The objective of this study was to develop new spirometric reference equations for the Korean population using the raw data of the fourth Korea National Health and Nutrition Examination Survey (KNHANES IV, 2007-2009). A total of 4,753 healthy lifelong nonsmokers without respiratory diseases and symptoms were selected as the reference population. Spirometric reference equations were derived through multiple regression analysis. The newly developed reference equations for spirometry parameters were as follows: FEV1 (L) = -0.00025410 × (Age [years])2 + 0.00012644 × (Height [cm])2 - 0.00262 × Weight (kg) + 0.61493 (Men); FEV1 (L) = -0.00017538 × Age2 + 0.00009598 × Height2 - 0.00231 × Weight + 0.46877 (Women); FVC (L) = -0.00000219 × Age3 + 0.0000006995642 × Height3 + 1.19135 (Men); FVC (L) = 0.0167 × Age - 0.00030284 × Age2 + 0.0000005850287 × Height3 + 0.77609 (Women); FEV1/FVC (%) = -0.00289 × Age2 - 0.16158 × Height3 + 114.13736 (Men); FEV1/FVC (%) = -0.21382 × Age - 0.00000143 × Height3 + 97.62514 (Women). The newly developed spirometric reference equation in this study can be used as criteria for the interpretation of spirometry results and the diagnosis of respiratory diseases in Korean adults.
机译:这项研究的目的是使用第四次韩国国家健康与营养检查调查(KNHANES IV,2007-2009年)的原始数据,为韩国人口开发新的肺活量测定参考方程式。总共选择了4,753名没有呼吸道疾病和症状的健康终生不吸烟者作为参考人群。肺功能参考方程是通过多元回归分析得出的。新开发的肺活量测定参数参考公式如下:FEV1(L)= -0.00025410×(年龄[年]) 2 + 0.00012644×(高度[cm]) 2 -0.00262×重量(kg)+ 0.61493(男性); FEV1(L)= -0.00017538×年龄 2 + 0.00009598×身高 2 -0.00231×体重+ 0.46877(女性); FVC(L)= -0.00000219×年龄 3 + 0.0000006995642×高度 3 + 1.19135(男性); FVC(L)= 0.0167×年龄-0.00030284×年龄 2 + 0.0000005850287×身高 3 + 0.77609(女性); FEV1 / FVC(%)= -0.00289×年龄 2 -0.16158×身高 3 + 114.13736(男性); FEV1 / FVC(%)= -0.21382×年龄-0.00000143×身高 3 + 97.62514(女性)。这项研究中新开发的肺功能测定参考方程式可以用作解释成人肺功能测定结果和诊断呼吸系统疾病的标准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号