Area under a receiver-operating-characteristic (AUROC) curve is widely used in medicine to summarize the ability of a continuous predictive marker to predict a binary outcome. This study illustrated how a U-shaped or inverted U-shaped continuous predictor would affect the shape and magnitude of its AUROC curve in predicting a binary outcome by comparing the ROC curves of the worst first 24-hour arterial pH values of 9549 consecutive critically ill patients in predicting hospital mortality before and after centering the predictor by its mean or median. A simulation dataset with an inverted U-shaped predictor was used to assess how this would affect the shape and magnitude of the AUROC curve. An asymmetrical U-shaped relationship between pH and hospital mortality, resulting in an inverse-sigmoidal ROC curve, was observed. The AUROC substantially increased after centering the predictor by its mean (0.611 vs 0.722, difference = 0.111, 95% confidence interval [CI] 0.087–0.135), and was further improved after centering by its median (0.611 vs 0.745, difference = 0.133, 95%CI 0.110–0.157). A sigmoidal-shaped ROC curve was observed for an inverted U-shaped predictor. In summary, a non-linear predictor can result in a biphasic-shaped ROC curve; and centering the predictor can reduce its bias towards null predictive ability.
机译:接收者操作特征(AUROC)曲线下的面积广泛用于医学中,以总结连续预测标记预测二进制结果的能力。这项研究通过比较9549例连续危重患者的最严重的前24小时动脉pH值的ROC曲线,说明了U型或倒U型连续预测器在预测二元结果时将如何影响其AUROC曲线的形状和大小。患者在通过平均数或中位数将预测器居中之前和之后预测医院死亡率。使用具有倒U形预测变量的模拟数据集来评估这将如何影响AUROC曲线的形状和大小。观察到pH与医院死亡率之间呈不对称的U形关系,导致ROC曲线呈反S形。在将预测值以其平均值居中之后,AUROC显着增加(0.611 vs 0.722,差异= 0.111,95%置信区间[CI] 0.087-0.135),在以中心值居中(0.611 vs 0.745,差异= 0.133,则进一步提高了) 95%CI 0.110–0.157)。对于倒U形预测变量,观察到S形ROC曲线。总而言之,非线性预测器可导致双相形状的ROC曲线。使预测变量居中可以减少其对无效预测能力的偏见。

著录项

  • 期刊名称 Scientific Reports
  • 作者

    Kwok M. Ho;

  • 作者单位
  • 年(卷),期 -1(7),-1
  • 年度 -1
  • 页码 10155
  • 总页数 7
  • 原文格式 PDF
  • 正文语种
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号