The Bull’s Eye Pattern of the Tear Film in Humans during Visual Fixation on En-Face Optical Coherence Tomography

机译:En-face光学相干层析成像的视觉固定过程中人眼泪膜的牛眼图案

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of the study was to define and characterize the optical behavior of the tear film during visual fixation in humans on en-face optical coherence tomography (OCT). We included 20 healthy participants, 60% female, aged from 25 to 42 years (33.05 ± 4.97 [mean ± SD]) and ten patients with severe dry eye, 50% female, aged from 26 to 42 years (33.7 ± 5.31). To perform high-resolution tear film imaging, participants were asked to gaze at the internal fixation point in the spectral-domain anterior segment OCT device, and meanwhile scanning session was executed at the following time-points after blinking: at the 2nd, 3rd, 4th, 5th, and 6th second. After one hour, OCT imaging was repeated (second session) by a different operator masked to the study to verify the reliability of results. During each measuring session, a pulse oximetry was used for continuously measuring the heart rate and oxygen saturation (SpO2%). A preliminary experiment was also performed to test the absence of geometric patterns from the anterior surface of a motionless artificial eye. OCT imaging showed a motionless, stable anterior surface of the artificial eye and in dry eye patients. Conversely, in the healthy participants of the study, a bull’s eye pattern of the tear film was detected by OCT at the 2nd, 3rd, 4th, 5th, and 6th second after blinking, respectively, in 45%, 60%, 45%, 60%, and 40% of OCT scans during the first session, and in 35%, 65%, 65%, 60%, and 35% of cases in the second session. Overall, a total of 200 OCT scans were performed in normal human population. A significant correlation was found between the novel tear film pattern and heart rate during the first and the second session (p < 0.01) in healthy eyes. Conversely, no correlation was revealed with SpO2%. Intraclass correlation (ICC) analysis for OCT imaging of the tear film revealed a statistically significant reproducibility of the results (ICC = 0.838; p < 0.01), indicating the high level of reliability of the method, independently of heart rate and SpO2% variables. There exists a novel, geometric pattern of the tear film during visual fixation detectable by en-face OCT, which is mainly evident as heart rate increases. Its discovery implies in turn the presence of a specific vibration (or imperceptible motion) of the tear film that, at present, is not recognized and corrected by the OCT software (in image postprocessing) unlike other eyeball movements.
机译:这项研究的目的是定义和表征人眼在表面光学相干断层扫描(OCT)上进行视觉固定时泪膜的光学行为。我们纳入了20名健康参与者,其中60%为女性,年龄在25至42岁之间(33.05±4.97 [平均值±SD]);十名重度干眼患者,其中50%为女性,年龄在26至42岁之间(33.7±5.31)。为了执行高分辨率泪膜成像,要求参与者凝视光谱域前节OCT设备的内部固定点,同时在眨眼后的以下时间点执行扫描会话:在2 nd ,3 rd ,4 th ,5 和6 秒。一小时后,由另一位对研究隐蔽的操作员重复进行OCT成像(第二次),以验证结果的可靠性。在每次测量过程中,使用脉搏血氧仪连续测量心率和血氧饱和度(SpO2%)。还进行了初步实验,以测试不动的人造眼前表面是否存在几何图案。 OCT成像显示假眼和干眼患者的动静,稳定的前表面。相反,在该研究的健康参与者中,OCT在2 ,3 rd ,4 th <眨眼后,分别在/ sup>,5 和5 秒内进行了45%,60%,45%,60%和40%的OCT扫描第一届会议,第二届会议分别占35%,65%,65%,60%和35%的案件。总体而言,在正常人群中总共进行了200次OCT扫描。在健康的眼睛中,新的泪膜模式与第一和第二阶段的心率之间存在显着相关性(p <0.01)。相反,没有发现与SpO2%相关。对泪膜进行OCT成像的类内相关(ICC)分析表明,该结果具有统计学意义的可重复性(ICC = 0.838; p <0.01),表明该方法具有很高的可靠性,而与心率和SpO2%变量无关。存在通过眼部OCT检测到的视觉固定期间泪膜的新颖的几何图案,这主要随着心率的增加而明显。它的发现又暗示眼泪膜存在特定的振动(或无法觉察的运动),该振动目前不像其他眼球运动那样被OCT软件(在图像后处理中)识别和校正。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号