摘要

The first experimental characterization of a multiple energy analysis wide angle backend for a cold triple-axis spectrometer is reported. The multi-analyzer module MultiFLEXX employs 155 detection channels which simultaneously probe an extensive range in wavevector and energy transfer. Successful mapping of magnetic excitations in MnF2 and Ho demonstrate order of magnitude gains in data collection efficiency using this novel type backend. MultiFLEXX is competitive to standard triple-axis spectroscopy in terms of energy resolution and signal-to-noise ratio. A minority of the detector channels is affected by spurious signals inherent to this multiplexing concept. The characteristic signature of these spurious signals easily allows for their discrimination. The instrument concept focuses on detection efficiency in the horizontal scattering plane which makes it an ideal technique for fast mapping and parametric studies including extreme sample environment.
机译:报告了冷三轴光谱仪的多能量分析广角后端的首次实验表征。多功能分析仪模块MultiFLEXX拥有155个检测通道,可同时探测广泛的波矢和能量传输。 MnF2和Ho中磁激发的成功映射证明了使用这种新颖类型的后端在数据收集效率方面的数量级增益。就能量分辨率和信噪比而言,MultiFLEXX在标准三轴光谱学方面具有竞争力。少数检测器通道会受到此复用概念固有的杂散信号的影响。这些杂散信号的特征签名很容易对其进行区分。仪器概念专注于在水平散射平面上的检测效率,这使其成为用于快速绘图和参数研究(包括极端样品环境)的理想技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号