Comparison of the accuracy of 99mTc-3P4-RGD2 SPECT and CT in diagnosing solitary pulmonary nodules

机译:99mTc-3P4-RGD2 SPECT和CT在孤立性肺结节诊断中的准确性比较

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of the present study was to compare technetium-99m-(polyethylene glycol-4)3-(Arg-Gly-Asp)2 (99mTc-3P4-RGD2) single-photon emission computed tomography (SPECT) and computed tomography (CT) in the noninvasive differentiation of solitary pulmonary nodules (SPNs). The present study prospectively investigated a consecutive series of 24 patients with SPN, who were newly diagnosed using radiography between September 2012 and January 2014. All patients underwent 99mTc-3P4-RGD2 SPECT and CT scans using a dual-head variable-angle γ-camera equipped with high-resolution collimators. A blinded panel of two thoracic radiologists for CT and three nuclear physicians for SPECT analyzed the images using a 5-grade scale. The SPECT images were also semi-quantitatively evaluated using tumor to non-tumor localization ratios (T/NT). The results were verified by pathological examination of the biopsy material obtained from each patient with SPN, and receiver operating characteristic (ROC) curves were generated from these results. The present results revealed that there were 17 malignant and 7 benign SPNs among the 24 patients with SPN. The mean size of the SPN was 2.1±0.6 cm. Sensitivity of visual analysis for SPECT and CT were 100.0 and 82.4%, respectively, and specificity was 71.4% for the two methods. When the T/NT SPECT semiquantitative analysis (ratio, 1.64) was used as a cut-off, the sensitivity and specificity of SPECT were 100.0 and 71.4%, respectively. The areas under the ROC curves were 0.840 for visual analysis of SPECT [95% confidence interval (CI), 0.600–1.000], 0.849 for semiquantitative analysis of SPECT (95% CI, 0.618–1.000) and 0.815 for CT (95% CI, 0.626–1.000). In conclusion, the present results suggest that 99mTc-3P4-RGD2 SPECT is more accurate than CT in the detection of malignant SPN, and visual analysis appears to be sufficient for the characterization of SPN.
机译:本研究的目的是比较tech 99m-(聚乙二醇4)3-(Arg-Gly-Asp)2(99mTc-3P4-RGD2)单光子发射计算机断层扫描(SPECT)和计算机断层扫描(CT) )在孤立性肺结节(SPNs)的非侵入性分化中。本研究前瞻性调查了连续24例SPN患者,这些患者在2012年9月至2014年1月之间通过放射线照相术新诊断。所有患者均接受了99mTc-3P4-RGD2 SPECT和CT检查,并使用了双头可变角度γ照相机配备高分辨率准直器。由两名CT的胸部放射线医师和SPECT的三名核医师组成的盲区使用5级标度对图像进行了分析。还使用肿瘤与非肿瘤的定位比(T / NT)对SPECT图像进行了半定量评估。通过对从每位SPN患者获得的活检材料进行病理检查来验证结果,并根据这些结果生成接收器工作特征(ROC)曲线。目前的结果显示,在24例SPN患者中,有17例恶性SPN和7例良性SPN。 SPN的平均大小为2.1±0.6 cm。视觉分析对SPECT和CT的敏感性分别为100.0和82.4%,两种方法的特异性为71.4%。当使用T / NT SPECT半定量分析(比率1.64)作为临界值时,SPECT的敏感性和特异性分别为100.0和71.4%。对于SPECT的视觉分析,ROC曲线下的面积为0.840 [95%置信区间(CI),0.600-1.000],对SPECT的半定量分析为0.849(95%CI,0.618-1.000),对于CT(95%CI为0.815) ,0.626–1.000)。总之,目前的结果表明99mTc-3P4-RGD2 SPECT在检测恶性SPN方面比CT更准确,并且视觉分析似乎足以表征SPN。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号