There have been many studies on glass particle contamination from glass ampules during the injection of glass ampules, but only the contamination from direct IV bolus injection has been measured. This research aimed to study the difference in glass particle contamination from ampules with different intravenous administration methods commonly used in clinical practice. Four methods were studied: IV bolus injection directly after immediate aspiration, IV bolus injection directly after 2 min’ delayed aspiration, IV bolus injection directly after aspiration with a filter needle, and side shooting to an infusion set with an in-line filter. 45 ampules per method for a total of 180 ampules were used. The number and length of glass particles were measured using a slide scanner. Aspiration was performed without specifically using a slow aspiration method. The longest glass particle was observed in the immediate aspiration group. The side shooting group showed the lowest maximum number of glass particles per ampule. The side shooting group also showed the smallest number of glass particles, but it was statistically insignificant. Using a filter needle syringe and 2 min’ delayed aspiration, which are frequently recommended to minimize contamination, may not be as effective as commonly believed, unless combined with a slow and low pressure aspiration method. Using a side shooting to an infusion set with an in-line filter may minimize glass particle contamination from ampules even without a slow and low pressure aspiration method, but more evidence from a larger study is needed.
机译:关于玻璃安瓿注射过程中来自玻璃安瓿的玻璃颗粒污染已有许多研究,但仅测量了直接静脉推注注射产生的污染物。本研究旨在通过临床实践中常用的不同静脉内给药方法研究安瓿瓶中玻璃微粒污染的差异。研究了四种方法:立即抽吸后立即进行静脉推注注射,延迟抽吸2分钟后立即进行IV推注注射,抽吸后直接使用滤针进行IV推注注射,并侧面注射至带有在线过滤器的输液器。每种方法使用45安瓿,总共使用180安瓿。使用载玻片扫描仪测量玻璃颗粒的数量和长度。没有特别使用慢速抽吸方法进行抽吸。在即时抽吸组中观察到最长的玻璃颗粒。侧面射击组显示出每安瓿最大的玻璃颗粒数量最低。侧面射击组也显示出最少的玻璃颗粒,但从统计学上来说是无关紧要的。通常建议使用滤针注射器和2分钟的延迟抽吸来减少污染,除非结合慢速和低压抽吸方法,否则效果可能不如通常所见。即使没有慢速和低压抽吸方法,对带在线过滤器的输液器进行侧面拍摄也可以最大程度地减少安瓿中的玻璃颗粒污染,但是需要来自更大研究的更多证据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号