摘要

Electrical impedance spectroscopy has been investigated with but limited success as an adjunct procedure to mammography and as a possible pre-screening tool to stratify risk for having or developing breast cancer in younger women. In this study, the authors explored a new resonance frequency based [resonance electrical impedance spectroscopy (REIS)] approach to identify breasts that may have highly suspicious abnormalities that had been recommended for biopsies. The authors assembled a prototype REIS system generating multifrequency electrical sweeps ranging from 100 to 4100 kHz every 12 s. Using only two probes, one in contact with the nipple and the other with the outer breast skin surface 60 mm away, a paired transmission signal detection system is generated. The authors recruited 150 women between 30 and 50 years old to participate in this study. REIS measurements were performed on both breasts. Of these women 58 had been scheduled for a breast biopsy and 13 had been recalled for additional imaging procedures due to suspicious findings. The remaining 79 women had negative screening examinations. Eight REIS output signals at and around the resonance frequency were computed for each breast and the subtracted signals between the left and right breasts were used in a simple jackknifing method to select an optimal feature set to be inputted into a multi-feature based artificial neural network (ANN) that aims to predict whether a woman’s breast had been determined as abnormal (warranting a biopsy) or not. The classification performance was evaluated using a leave-one-case-out method and receiver operating characteristics (ROC) analysis. The study shows that REIS examination is easy to perform, short in duration, and acceptable to all participants in terms of comfort level and there is no indication of sensation of an electrical current during the measurements. Six REIS difference features were selected as input signals to the ANN. The area under the ROC curve (Az) was 0.707±0.033 for classifying between biopsy cases and non-biopsy (including recalled and screening negative) and the performance (Az) increased to 0.746±0.033 after excluding recalled but negative cases. At 95% specificity, the sensitivity levels were approximately 20.5% and 30.4% in the two data sets tested. The results suggest that differences in REIS signals between two breasts measured in and around the tissue resonance frequency can be used to identify at least some of the women with suspicious abnormalities warranting biopsy with high specificity.
机译:已经对电阻抗光谱法进行了研究,但作为乳房X线照相术的辅助程序,以及作为对年轻女性患乳腺癌或罹患乳腺癌的危险进行分层的可能的预筛查工具,成功率有限。在这项研究中,作者探索了一种基于共振频率的新方法[共振电阻抗光谱(REIS)],以识别可能具有高度可疑异常的乳房,因此建议进行活检。作者组装了一个REIS系统原型,每12 s产生100至4100 kHz的多频电扫描。仅使用两个探针,一个与乳头接触,另一个与乳腺外皮肤表面相距60 mm,就可以生成一个配对的传输信号检测系统。作者招募了150位30至50岁的女性参加这项研究。对两个乳房进行REIS测量。在这些妇女中,有58名因可疑发现而被安排进行乳房活检,并召回13名进行额外的影像学检查。其余的79名妇女接受了阴性筛查检查。计算每个乳房在共振频率处和共振频率附近的八个REIS输出信号,并将左,右乳房之间相减后的信号用于简单的套叠方法中,以选择最佳特征集,以输入到基于多特征的人工神经网络中(ANN)的目的是预测女性的乳房是否被确定为异常(需要进行活检)。使用留一事例法和接收器工作特性(ROC)分析评估分类性能。研究表明,REIS检查易于执行,持续时间短,并且在舒适度方面对所有参与者都是可以接受的,并且在测量过程中没有迹象表明有电流感。选择了六个REIS差异特征作为ANN的输入信号。 ROC曲线下面积(Az)为0.707±0.033,用于在活检病例和非活检之间进行分类(包括召回和筛查阴性),排除召回但阴性的病例后,性能(Az)提高到0.746±0.033。在95%的特异性下,在两个测试数据集中的敏感性水平分别约为20.5%和30.4%。结果表明,在组织共振频率之内和附近测量的两个乳房之间的REIS信号差异可用于识别至少一些可疑异常的女性,从而需要进行高特异性活检。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号