Correction of breathing-induced errors in magnetic resonance thermometry of hyperthermia using multiecho field fitting techniques

机译:使用多回波场拟合技术校正热疗磁共振测温中呼吸引起的误差

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

>Purpose: Breathing motion can create large errors when performing magnetic resonance (MR) thermometry of the breast. Breath holds can be used to minimize these errors, but not eliminate them. Between breath holds, the referenceless method can be used to further reduce errors by relying on regions of nonheated fatty tissue surrounding the heated region. When the surrounding tissue is heated (i.e., for a hyperthermia treatment), errors can result due to phase changes of the small amounts of water in the tissue. Therefore, an extension of the referenceless method is proposed which fits for the field in fatty tissue independent of temperature change and extrapolates it to the water-rich regions.>Methods: Nonheating experiments were performed with male volunteers performing breath holds on top of a phantom mimicking a breast with a tumor. Heating experiments were also conducted with the same phantom while mechanically simulated breath holds were performed. A nonheating experiment was also performed with a healthy female breast. For each experiment, a nonlinear fitting algorithm was used to fit for temperature change and B0 field inside of the fatty tissue. The field changes were then extrapolated into water-rich (tumor) portions of the image using a least-squares fit to a fifth-order equation, to correct for field changes due to breath hold changes. Similar results were calculated using the image phase, to mimic the use of the referenceless method.>Results: Phantom results showed large reduction of mean error and standard deviation. In the non-heating experiments, the traditional referenceless method and our extended method both corrected by similar amounts. However, in the heating experiments, the average deviation of the temperature calculated with the extended method from a fiber optic probe temperature was approximately 50% less than the deviation with the referenceless method. The in vivo breast results demonstrated reduced standard deviation and mean.>Conclusions: In this paper, we have developed an extension of the referenceless method to correct for breathing errors using multiecho fitting methods to fit for the B0 field in the fatty tissue and using measured field changes as references to extrapolate field corrections into a water-only (tumor) region. This technique has been validated in a number of situations, and in all cases, the correction method has been shown to greatly reduce temperature error in water-rich regions. The method has also been shown to be an improvement over similar methods that use image phase changes instead of field changes, particularly when temperature changes are induced.
机译:>目的:进行乳房磁共振(MR)体温测量时,呼吸运动会产生较大的误差。屏气可以使这些错误最小化,但不能消除。在屏气之间,无参考方法可用于依靠围绕加热区域的非加热脂肪组织区域来进一步减少错误。当周围的组织被加热时(即,用于热疗),由于组织中少量水的相变而可能导致误差。因此,提出了一种无参考方法的扩展方法,该方法适用于脂肪组织中不受温度变化影响的领域,并将其外推到富水区域。>方法:非加热实验是在男性志愿者进行呼气时进行的放在模仿乳房肿瘤的幻像上。在进行机械模拟屏气的同时,还使用相同的体模进行了加热实验。还对健康的女性乳房进行了不加热实验。对于每个实验,都使用非线性拟合算法来拟合脂肪组织内部的温度变化和B0场。然后使用与五阶方程拟合的最小二乘法将场变化外推到图像的富水(肿瘤)部分中,以校正因屏气而引起的场变化。使用图像相位计算相似的结果,以模仿无参考方法的使用。>结果:幻影结果显示平均误差和标准偏差大大降低。在非加热实验中,传统的无参考方法和我们的扩展方法都以相似的量进行了校正。但是,在加热实验中,用扩展方法计算的温度与光纤探针温度的平均偏差比无参考方法的偏差小约50%。体内乳房结果显示标准偏差和均值降低。>结论:在本文中,我们开发了无参考方法的扩展,以使用多重回波拟合方法来拟合B0字段中的呼吸错误来校正呼吸错误。脂肪组织,并使用测量到的场变化作为参考,将场校正外推到纯水(肿瘤)区域。该技术已在许多情况下得到验证,并且在所有情况下,都显示出该校正方法可以大大减少富水地区的温度误差。与使用图像相位变化而不是场变化的类似方法相比,该方法也已显示出改进,尤其是在引起温度变化时。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号