首页> 美国卫生研究院文献>Journal of Nuclear Medicine >Accuracy and Reproducibility of Absolute Quantification of Myocardial Focal Tracer Uptake from Molecularly Targeted SPECT/CT: A Canine Validation
【2h】

Accuracy and Reproducibility of Absolute Quantification of Myocardial Focal Tracer Uptake from Molecularly Targeted SPECT/CT: A Canine Validation

机译:从分子靶向的SPECT / CT对心肌局部示踪剂摄取的绝对定量的准确性和可重复性:犬验证。

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Accurate and reproducible SPECT quantification of myocardial molecular processes remains a challenge because of the complication of heterogeneous background and extracardiac activity adjacent to the heart, which causes errors in the estimation of myocardial focal tracer uptake. Our aim in this study was to introduce a heuristic method for the correction of extracardiac activity into SPECT quantification and validate the modified quantification method for accuracy and reproducibility using a canine model.MethodsDual-isotope–targeted 99mTc and 201Tl perfusion SPECT images were acquired using a hybrid SPECT/CT camera in 6 dogs at 2 wk after myocardial infarction. Images were reconstructed with and without CT-based attenuation correction, and the reconstructed SPECT images were filtered and quantified simultaneously with incorporation of extracardiac radioactivity correction, gaussian fitting, and total-count sampling. Absolute myocardial focal tracer uptake was quantified from SPECT images using 3 different normal limits (maximum entropy [ME], mean-squared-error minimization [MSEM], and global minimum [GM]). SPECT-quantified percentage injected dose (%ID) was calculated and compared with the well-counted radioactivity measured from the postmortem myocardial tissue. SPECT quantitative processing was performed by 2 different individuals with extensive experience in cardiac image processing, to assess reproducibility of the quantitative analysis.
机译:由于异质背景和邻近心脏的心脏外活动的并发症,对心肌分子过程进行准确且可重现的SPECT定量分析仍然是一个挑战,这会导致心肌局部示踪剂摄取的估计错误。我们在这项研究中的目的是将一种用于校正心脏外活动的启发式方法引入SPECT量化中,并使用犬模型对改进的量化方法的准确性和可重复性进行验证。方法以双同位素为目标的 99m Tc和在心肌梗死后2周,使用混合SPECT / CT相机在6只狗中获取了 201 T1灌注SPECT图像。使用和不使用基于CT的衰减校正来重建图像,并结合心外放射性校正,高斯拟合和总计数采样,同时对重建的SPECT图像进行滤波和量化。使用3种不同的正常限度(最大熵[ME],均方误差最小化[MSEM]和全局最小[GM])从SPECT图像中量化绝对心肌局灶示踪剂摄取。计算SPECT量化的注射剂量百分比(%ID),并将其与从死后心肌组织测得的计数准确的放射性进行比较。由2位在心脏图像处理方面具有丰富经验的不同个人执行SPECT定量处理,以评估定量分析的可重复性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号