To assess the coagulation capability of a perfusion microwave electrode (PME) as a key component of microwave coagulation therapy, a preliminary experimental study was performed using ex vivo and in vivo livers. For a microwave electrode, a PME was employed. Using a PME, saline was passed through the electrode and injected continuously into the target tissue. Using an ex vivo bovine liver, the range of tissue coagulation was measured for various volumes of infused saline and microwave outputs. Using an in vivo porcine liver, the efficiency of coagulation by a PME was compared with that of radiofrequency ablation (RFA) using a cool-tip needle. In an ex vivo bovine liver, the range of tissue coagulation increased as the flow rate of saline increased. In the in vivo porcine liver, the range of coagulation was similar to that found in the ex vivo bovine liver. With a PME under conditions of a microwave output of 80 W, a flow rate of 3 ml/min and irradiation time of 5 min, the range of coagulation was 44.8±2.8 mm [maximum vertical diameter: (a)] x 31.2±2.4 mm [maximum transverse diameter: (b)]. The range of RFA (cool-tip needle) at 12 min was 46.0±2.0 mm (a) x 30.2±2.0 mm (b). With only 5 min of microwave irradiation, the use of a PME enabled induction of the same range of coagulation that was obtainable by RFA for 12 min. In comparison with microwave coagulation without saline infusion, the use of a PME made it possible to extend the range of tissue coagulation to a range equal to that of RFA in a short time. Microwave coagulation using a PME may be one of the suitable tissue coagulation systems for local ablation treatment.
机译:为了评估作为微波凝结治疗关键成分的灌注微波电极(PME)的凝结能力,使用离体和体内肝脏进行了初步实验研究。对于微波电极,使用PME。使用PME,盐水穿过电极并连续注入目标组织。使用离体牛肝,测量各种体积的注入盐水和微波输出的组织凝结范围。使用体内猪肝,将PME的凝结效率与使用冷尖针的射频消融(RFA)的凝结效率进行了比较。在离体牛肝中,组织凝结的范围随着盐水流速的增加而增加。在体内猪肝中,凝血范围与离体牛肝中相似。对于PME,在80 W微波输出,3 ml / min的流速和5 min的照射时间的条件下,凝固范围为44.8±2.8 mm [最大垂直直径:(a)] x 31.2±2.4 mm [最大横向直径:(b)]。 12分钟时RFA(冷尖针)的范围是46.0±2.0 mm(a)x 30.2±2.0 mm(b)。仅用5分钟的微波辐射,使用PME就可以诱导与RFA进行12分钟相同凝结范围的诱导。与没有盐水注入的微波凝结相比,PME的使用使得可以在短时间内将组织凝结的范围扩大到等于RFA的范围。使用PME的微波凝结可以是用于局部消融治疗的合适的组织凝结系统之一。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号